CpuSwitchover
CpuSwitchover
(SmartSwitch 6500 Only)
Use CpuSwitchover to manually switch roles of the redundant (slave) and master TSM/CPU modules (the slave
module becomes the master module and vice versa). The
TSM/CPU module is present.
Note
CPU switchover occurs automatically if support for automatic TSM/CPU
redundancy has been activated and is operational. You activate automatic
TSM/CPU redundancy with the RedundancyOn attribute.
Operators
execute
Parameters
This attribute has no output parameters.
Input Parameter
Description
[BackupConfig]
Sets/unsets a flag to backup configuration.
Descriptions
Operator
Parameters/Permissions
[BackupConfig] <backupconfig>
execute
cpuswitchover
Administrator
Examples
switch_prompt # execute cpuswitchover
BackupConfig(N)
Backup the config and restore it on the redundant CPU when it boots up.
2-62 SmartSwitch ATM Switch Reference Manual
execute cpuswitchover
Value/Field Size
Y (Yes), N (No)
Description
Switches the slave TSM/CPU module to the master
TSM/CPU module and vice versa. The current
master configuration is backed up before the
switchover is made. After the switchover, the master
configuration is restored to the new master (the
module that was the slave before the switchover).
:
Console Commands
command is available only if a slave
Default
Y
Need help?
Do you have a question about the SmartSwitch 2500 and is the answer not in the manual?
Questions and answers