Lecselan - Cabletron Systems SmartSwitch 2500 Reference Manual

Enterasys smartswitch 2500: reference guide
Hide thumbs Also See for SmartSwitch 2500:
Table of Contents

Advertisement

LECSELAN

LECSELAN
Use LECSELAN to manage ELAN entries at the LECS.
Operators
add, delete, modify, show
Parameters
Input Parameter
Description
[ELANNumber]
Number of the ELAN to add to the LECS.
[ELANName]
Name of ELAN to add to the LECS.
[LESAddress]
Address of the LES associated with the ELAN. 13-20 byte hex-based/
[ELANType]
The data-link type used by the ELAN.
[MTU]
Maximum transfer unit for the clients joining
this ELAN.
[TLVSet]
The TLV (type, length, and value) set number
(set of TLV parameters) corresponding to the
members joining this ELAN.
Output Parameter
[ELAN Number]
[ELAN Name]
[LES Address]
[ELAN Type]
[MTU]
2-96 SmartSwitch ATM Switch Reference Manual
Description
Number of the ELAN to add to the LECS.
Name of ELAN to add to the LECS.
Address of the LES associated with the ELAN.
The data-link type used by the ELAN.
Maximum transfer unit for the clients joining this ELAN.
Value/Field Size
0-125
Up to 32 characters
59 characters
802.3 (Ethernet),
802.5 (Token Ring)
1516, 1580, 4544, or
9234
1-32767
Default
0
No default
No default
802.3
1516 or 4544
No default