TrafficDescriptor
Use TrafficDescriptor to manage traffic types.
Operators
add, delete, show
Parameters
Input Parameter
[TrafficType]
[TrafficDescriptorType]
[TrafficDescriptorIndex] Unique identifier for
[PCRCLP0+1]
[PCRCLP0]
[SCRCLP0+1]
Description
Value/Field Size
Service category
CBR, UBR, RTVBR, NRTVBR, ABR
supported.
Traffic descriptor
Seven possible combinations, represented by any
type.
of the following numbers: 2-7 or 11.
PeakCellRate CLP0+1 (2)
PeakCellRate CLP0+1, PeakCellRate CLP0 (3)
PeakCellRate CLP0+1, PeakCellRate CLP0,
PeakCellRate CLP0+1, SustCellRate CLP0+1,
PeakCellRate CLP0+1, SustCellRate CLP0,
PeakCellRate CLP0+1, SustCellRate CLP0,
BestEffort (11)
Positive integer
each traffic descrip-
tor. Use
show trafficde-
to get index
scriptor
numbers.
Peak cell rate
Zero or positive integer
CLP = 0+1
(KiloBits per second).
Peak cell rate CLP = 0
Zero or positive integer
(KiloBits per second).
Sustainable cell rate
Zero or positive integer
CLP = 0+1
(KiloBits per second).
Tag CLP = 1 (4)
MaxBurstSize CLP0+1(5)
MaxBurstSize CLP0 (6)
MaxBurstSize CLP0, Tag CLP = 1(7)
SmartSwitch ATM Switch Reference Manual 2-333
TrafficDescriptor
Default
UBR
2
No default
100
0
0