Summary of Contents for Cabletron Systems SmartSwitch 2500
Page 1
SmartSwitch ATM Switch Reference Manual 35 Industrial Way Rochester, NH 03866 (603) 332-9400 Part Number 04-0054-01 Rev. A Order Number 9033003...
Page 2
EPIM, EPIMA, EPIM-F1, EPIM-F2, EPIM-F3, EPIM-T, EPIM-X, FOT-F, FOT-F3, HubSTACK, SEH, SEHI, and TMS-3 are trademarks of Cabletron Systems, Inc. All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies. ii SmartSwitch ATM Switch Reference Manual...
Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. SmartSwitch ATM Switch Reference Manual iii...
89/336/EEC 73/23/EEC Cabletron Systems, Inc. 35 Industrial Way P. O. Box 5005 Rochester, NH 03866 SmartSwitch 2500 family and SmartSwitch 6500 Mr. J. Solari Cabletron Systems, Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England EC Directive 89/336/EEC...
Page 5
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, you must remove power from the network adapter. watts. or 8x10 SmartSwitch ATM Switch Reference Manual v sr-1.
Page 6
Reconnect cable and check for proper mating. If problems remain, gently wipe out optical port with a DRY fiber port cleaning swab and repeat step 1. To avoid contamination, replace port caps on all fiber optic devices when not Warning in use. vi SmartSwitch ATM Switch Reference Manual...
Page 7
REGULATORY COMPLIANCE SUMMARY SAFETY The SmartSwitch 2500 family and SmartSwitch 6500 meets the safety requirements of UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950, and 73/23/EEC. The SmartSwitch 2500 family and SmartSwitch 6500 meets the EMC requirements of FCC Part 15, EN 55022, CSA C108.8, VCCI V-3/93.01, EN 50082-1, and 89/336/EEC.
SmartSwitch ATM Switch Reference Manual Document Part Number: 04-0054-01 Rev. A Document Order Number: 9033003 Author: Robert de Peyster Editor: Ayesha Maqsood Illustrator: Mike Fornalski Date Revision "«Àˆ•Ê£™™™ 04-0054-01 Rev. A viii SmartSwitch ATM Switch Reference Manual Description Initial release...
1 INTRODUCTION This reference manual describes the console commands for the SmartSwitch 2500 family and the SmartSwitch 6500. Unless otherwise noted, the information in this manual applies to both the SmartSwitch 2500 family and SmartSwitch 6500. Audience and Scope The manual is intended for network administrators and others responsible for maintaining the SmartSwitch 2500 family and the SmartSwitch 6500.
There is also a table of commands at the end of this chapter. It lists all switch attributes by their operators. For details on how to use the SmartSwitch 2500 family or SmartSwitch 6500, see the SmartSwitch user guide that applies. Each SmartSwitch user guide contains task-oriented information on switch configuration, maintenance, and SNMP (simple network management protocol).
Introduction Abbreviations Pay attention to how switch attributes appear in section headings of Chapter 2. Switch attributes are not case sensitive, but you must spell them correctly. For example, if the heading states BUSStat, you must enter busstats. switch_prompt # show busstats...
Help Options Help Options The console provides several levels of help for console commands. For example, to list the switch attributes that can be used with a particular operator, enter the word switch_prompt # help add HELP ---- ============================================================================== [ Alias | ATMRoute | BUSELAN | Community | ELAN | Interface |...
Introduction Switch Attribute Entries Each switch attribute has an entry in Chapter 2. The entry starts with the attribute name and a brief explanation of the attribute’s purpose. Note A few switch attributes apply to the SmartSwitch 6500 only. Those attributes are indicated in Chapter 2 by the following notation after attribute name: (SmartSwitch 6500 Only).
Page 20
Upgrades firmware Parameters Most switch attributes have input or output parameters (or both). If an attribute has parameters, they are listed in tables under a “Parameters” heading. You enter input parameters at the console command line. You view output parameters at the console screen after the command executes.
Page 21
[ClientNumber] <clientnumber> clientvc Examples Examples are copied exactly from the switch console. They show how you enter console commands at the switch prompt (for example: modify buselan in brackets immediately following each parameter field indicates the current default (for example:...
Port Numbering Port Numbering Port numbering for the SmartSwitch 6500 is different from that for the SmartSwitch 2500 family. For the SmartSwitch 6500, physical port numbering uses the following format: slot number I/O module letter For example, port 3 of I/O module A on the TSM in slot 5 is represented by: For the SmartSwitch 2500 family, physical port numbering does not use slot numbers.
A few switch attributes apply to the SmartSwitch 6500 only. For those attributes, Note the following appears below the attribute name: (SmartSwitch 6500 Only). If this notation does not appear, the attribute applies to both the SmartSwitch 2500 family and to the SmartSwitch 6500. 622LoopBack Use 622LoopBack to set or display loopback on 622 Mbps (OC-12/STM-4) ports.
Page 30
Cells generated by the switch to this port are not sent over the line. Diag Connects the receiver to the transmitter. The data stream transmitted by the switch to a port is looped back to the switch.
: on switch_prompt # switch_prompt # show alarmdisplay Alarm Display is ON switch_prompt # Value/Field Size On, Off Description Toggles display of alarm messages on the console screen. Displays status of alarms display. SmartSwitch ATM Switch Reference Manual 2-3 AlarmDisplay Default...
Deletes an alarm or all alarms. Displays alarm(s) currently logged. Alarm information includes message index number, alarm ID, message text, severity, and a timestamp (time the alarm occurred, with respect to switch up-time in hours, minutes, seconds, and milliseconds). Console Commands Default...
Same as the [AliasedString] input parameter. Descriptions Operator Parameters/Permissions add alias [AliasName] <aliasname> [AliasedString] <aliasedstring> Administrator 2-6 SmartSwitch ATM Switch Reference Manual ʈÃÊ«ÀiÃi˜ÍÊÝ…i˜ÊÍ…iÊÃ݈ÍV…ʈÃÊÃ…ˆ««i`ÊvÀœ“ÊÍ…iÊv>VÍœÀßÊ- ®° Value/Field Size Single word (no spaces) of alphanumeric characters. Any valid combination of operator and attribute (for...
Page 35
Modifying Alias "spnni -> show pnniinterface" to "spnni -> sp" Confirm(y/n)?:y switch_prompt # Description Deletes an alias. Deletes all aliases (including Changes an alias. Displays all aliases. : spnni : show pnniinterface : spnni : spnni : sp SmartSwitch ATM Switch Reference Manual 2-7 Alias ping...
Page 36
Alias switch_prompt # show alias AliasName(ALL) Alias List ============================================================================== Index Alias Name PING switch_prompt # 2-8 SmartSwitch ATM Switch Reference Manual : Aliased Command : Start Ping : show pnninode Console Commands...
Console Commands AtmFilter Use AtmFilter to manage ATM filters on the switch. Operators add, delete, modify, show Parameters Input Parameter Description [AtmFilterName] Name of the filter. [AtmFilterType] Type of the filter. [SrcAtmAddress] Source (calling party) address (for which this filter should be applied).
1 filter is used, then priority 2 filter, and so forth until all filters have been used.) Type of a filter in the filter set. SmartSwitch ATM Switch Reference Manual 2-13 AtmFilterSet Default No default...
ATMRoute ATMRoute Use ATMRoute to manage routes to reachable addresses from the switch. The following applies to SmartSwitch 6500 only: You can hot-swap TSMs. Note Hot-swapping is replacing a module when the chassis is powered up. If you replace a TSM with another TSM of the same type (same I/O ports), existing configuration of port parameters is not affected.
Page 45
[Advertising Port Id] Identifier of the port used from the advertising node to reach the given address prefix. [PNNI Scope] PNNI scope of advertisement (level of PNNI hierarchy) of reachability from the switch to the address prefix. [VP Capability] Indicates whether or not VPCs can be established from the advertising node to the reachable address prefix.
Page 46
For reachable addresses learned by means other than PNNI, this parameter is set to zero. [Advertising] Whether or not the local switch advertises the local address into the PNNI domain. Possible values are: Yes and No. [Oper Status] Whether or not the reachable address prefix is operationally valid and whether it is advertised by this node.
Page 47
VP Capability : False Metrics Tag Ptse Id Advertising : No Oper Status : Active The ATM route was deleted successfully. switch_prompt # : 7a3 : 20:01:02:03 Type Proto : 20:01:02:03 SmartSwitch ATM Switch Reference Manual 2-19 ATMRoute I MGMT...
[ELANNumber] <elannumber> busclient [LecID] <lecidvalue> Administrator show [ELANNumber] <elannumber> busclient 2-20 SmartSwitch ATM Switch Reference Manual Value/Field Size 0-125 1-65279 Description Removes a specified client from the BUS on the specified ELAN. Displays information about all clients that have joined the BUS on the specified ELAN.
[ATM Address] ATM address associated with the error. [ErrorCode] Decimal code that shows why the error occurred (see Table 2-2). [SysUpTime] Time the error occurred with respect to switch up-time in hours, minutes, and seconds. Descriptions Operator Parameters/Permissions [ELANNumber] <elannumber>...
Page 51
Responder is unable to grant request for reasons such as insufficient table space or ability to establish VCCs. Malformed control frame or bad control request. Malformed data frame (too big or too small). All other events. ErrorCode SysUpTime 01:02:03 SmartSwitch ATM Switch Reference Manual 2-23 BUSErrorLog...
Output Parameter Description [ELAN Number] Number of the ELAN to which the BUS belongs. [ELAN Name] Name of the ELAN to which the BUS belongs. 2-24 SmartSwitch ATM Switch Reference Manual Console Commands Value/Field Size Default 0-125 or All PVC, SVC 802.3 (Ethernet),...
Page 53
ELAN. The specified ELAN is then deleted and recreated. If the corresponding LESELAN exists, then the modified BUSELAN should have the same characteristics as that existing LESELAN because their parameters need to match. SmartSwitch ATM Switch Reference Manual 2-25 BUSELAN...
Page 54
ELANNumber(0) ELAN Number ELAN Name : ELAN003 ATM Address : 39:00:00:00:00:00:00:00:20:D4:14:15:00:00:20:D4:14:15:03:02 Confirm(y/n)? switch_prompt # 2-26 SmartSwitch ATM Switch Reference Manual Description Displays the BUS parameters for the specified ELAN. Enter show buselan changes you made. : 102 Console Commands to confirm that...
Page 55
: 4544 Connection Method : SVC Distribute VPI/VCI : 0/2423 Sel.DistributeVPI/VCI: 0/2423 ELAN Type : 802.5 Multipoint : YES Error Logging : NO Min TD Negotiation : NO switch_prompt # : 802.5 : 4544 SmartSwitch ATM Switch Reference Manual 2-27 BUSELAN...
Number of requests discarded by the BUS from this LEC. Descriptions Operator Parameters/Permissions [ELANNumber] <elannumber> show [LecId] <lecidvalue> buslecstat 2-28 SmartSwitch ATM Switch Reference Manual Value/Field Size 0-125 or All 0-65279 Description Displays statistical information about a specific client or all clients on that ELAN. Console Commands...
[ELANNumber] <elannumber> clear busstat Administrator 2-30 SmartSwitch ATM Switch Reference Manual Value/Field Size Description Displays BUS statistics for the specified ELAN or for all ELANs. Clears BUS statistics for the specified ELAN or for all ELANs. Console Commands...
Page 59
: 7030 Out Multicast In Octets : 450432 In Unicast : 7030 In Multicast Frame Timeouts VCC Rejects switch_prompt # switch_prompt # clear busstat ELANNumber(ALL): Clearing ALL BUS ELAN Statistics Confirm(y/n)?:y switch_prompt # SmartSwitch ATM Switch Reference Manual 2-31 BUSStat...
Console Commands CACEqBwAllocScheme Use CACEqBwAllocScheme to set or display the equivalent bandwidth allocation scheme of switch ports. Operators modify, show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. [ServiceCategory] Service category.
Console Commands CacInfo Use CacInfo to display bandwidth allocated to switch ports per service category. Operators show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. [BandwidthUnit] Unit for specifying bandwidth.
Page 64
Examples switch_prompt # show cacinfo PortNumber(ALL) BandWidthUnit(CPS) ===================================================================== Port# Total Total BW Allocated ===================================================================== 264186 264186 264186 264186 264186 264186 264186 switch_prompt # 2-36 SmartSwitch ATM Switch Reference Manual : ALL : CPS BwAlloc For ServiceCategory RT-VBR NRT-VBR Console Commands...
Console Commands CACPortBw Use CACPortBw to display minimum and maximum bandwidth of switch ports. Operators show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. Output Parameter Q+œÀÍ›R Q >Þ*>˜`݈`Í…7˜ L«ÃR Q >Þ*>˜`݈`Í…7˜=L«ÃR...
A1.n to B4.n (virtual-2500 family), 1A1 to 8B4 (physical-6500), 1A1.n to 8B4.n (virtual-6500), or All CBR, UBR, RTVBR, NRTVBR, ABR UBR >Þˆ“Ö“ÊL>˜`݈`Í…Ê Zero or positive integer Zero or positive integer >Þˆ“Ö“ÊL>˜`݈`Í…Ê Zero or positive integer SmartSwitch ATM Switch Reference Manual 2-39 CACServiceClassBw Default...
Page 68
ABR. Output Parameter Description [Port#] Port number on the switch. (Same as [PortNumber] input parameter. [SC] Service category. (Same as [ServiceCategory] input parameter.) [Max Bandwidth In Mbps) Maximum bandwidth in MegaBits per second allocated to the service category specified.
CACStatistics CACStatistics Use CACStatistics to show CAC statistics for switch ports. Operators clear, show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. Output Parameter Description [Port Number] Physical or virtual port number on the switch.
Page 71
No of ABR calls HIGH threshold exceeded No of ABR calls LOW threshold exceeded No of PNNI Updates sent Total No of calls HIGH threshold exceeded Total No of calls LOW threshold exceeded switch_prompt # : 1a1 :1A1 SmartSwitch ATM Switch Reference Manual 2-43 CACStatistics...
Client Client Use Client to manage LANE and IP/ATM clients on the switch. Clients on the switch are called local clients. Use the LANEClient attribute to add or modify a LANE client. Use the Note IPATMClient attribute to add or modify an IP/ATM client.
Page 73
Deactivates a client on the switch. Removes a client from the switch. Restarts a client on the switch. If a client fails to successfully join a VLAN, you can restart the client to retry. The switch software, on a periodic basis, automatically tries to restart clients that have not successfully joined.
Page 74
# switch_prompt # show client /s ClientNumber(ALL) Client Type IP Address ============================================================================ LANE 90.1.1.186 IP/ATM 90.1.1.124 switch_prompt # 2-46 SmartSwitch ATM Switch Reference Manual Server Type Server Conn Status LECS Established Operational Local Established Operational Server Type Server Conn...
Page 75
# show client 3 /d IP/ATM Client 3 ============================================================================ Client State : Operational Client Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:00:5A:01:01:7C:00 Server : is local Server Connection: Established : 9180 IP Address : 90.1.1.124 IP NetMask : 255.0.0.0 switch_prompt # SmartSwitch ATM Switch Reference Manual 2-47 Client...
ClientARP Use ClientARP to display the ARP table maintained by each LANE or IP/ATM client on the switch. For a LANE client, the table contains mappings of MAC to ATM addresses for destination clients. The mappings are supplied by the ARP server of each ELAN to which the LANE client connects.
ClientStat ClientStat Use ClientStat to display packet count statistics of LANE or IP/ATM clients on the switch. Clients on the switch are called local clients. Note Operators show Parameters Input Parameter [ClientNumber] In the Output Parameter table below, (detailed) command. The (IP/ATM) and (LANE) client indicators after particular parameters indicate clientstat /d that these parameters display only if that particular client type is active.
Page 79
Number of clients who failed to join the SVC (switched virtual circuit). ARP unreachable clients. Number of inverse ARP NAKs (negative acknowledges) received. Number of echo discards. Number of filtered multicasts. Number of flow failures. Description Displays packet count statistics for local clients. SmartSwitch ATM Switch Reference Manual 2-51 ClientStat...
ClientVC ClientVC Use ClientVC to display VCs associated with ARP mappings cached by LANE or IP/ATM clients on the switch. ClientARP is similar to ClientVC but does not show the VPI/VCI corresponding to a route to a destination client. Note Clients on the switch are called local clients.
Use Community to group NMS (network management system) hosts by privilege level. Hosts are collectively called communities. Host privilege levels determine the type of information access permitted by the switch. The switch provides access to the information only if the request comes from a community configured with the necessary privileges.
Page 85
ILMI public zeitnet switch_prompt # : boris : 90.1.1.1 IP Address Privilege 0.0.0.0 READ 90.1.1.1 READ 0.0.0.0 READ 0.0.0.0 WRITE : boris : 90.1.1.1 IP Address Privilege 0.0.0.0 READ 0.0.0.0 READ 0.0.0.0 WRITE SmartSwitch ATM Switch Reference Manual 2-57 Community...
Examples switch_prompt # clear config You should backup your configuration using the "backup switch" command, in case you want to recover this configuration Continuing will permanently erase the current switch configuration, and requires a switch reboot. Are you sure this is what you want to do? Confirm(y/n)?:y Configuration cleared.
[CoreDumpServerIP] IP address of host to which the core is dumped. (Same as the [ServerIP] input parameter.) [CoreDumpFile] Full pathname of the file to which the core is dumped. 2-60 SmartSwitch ATM Switch Reference Manual Console Commands Value/Field Size Default...
Page 89
The core dump takes about five minutes. After the core dump, the switch is rebooted. The core is dumped to two files, one containing CPU memory (core_cpu), the other common memory (core_cmn).
CpuSwitchover CpuSwitchover (SmartSwitch 6500 Only) Use CpuSwitchover to manually switch roles of the redundant (slave) and master TSM/CPU modules (the slave module becomes the master module and vice versa). The TSM/CPU module is present. Note CPU switchover occurs automatically if support for automatic TSM/CPU redundancy has been activated and is operational.
Console Commands CsmSwitchover (SmartSwitch 6500 Only) Use CsmSwitchover to manually switch roles of the redundant (slave) and master CSM modules (the slave module becomes the master module and vice versa). The module is present. Note The switch supports automatic CPU switchover but does not support automatic CSM switchover.
Line Connects the transmitter to the receiver. The DS3 or E3 stream received from the line is retransmitted back out to the line. Cells generated by the switch to this port are not sent over the line. Diag Connects the receiver to the transmitter. The DS3 or E3 stream transmitted by the switch to a port is looped back to the switch.
ELAN ELAN Use ELAN to create or delete ELANs on the switch. It is a means to manage ELAN servers with one command. To manage ELAN servers individually, see the BUSELAN, LECSELAN, and LESELAN attributes. Note The BUSELAN, LECSELAN, and LESELAN attributes manage, respectively, the Broadcast and Unknown Server (BUS), LAN Emulation Configuration Server (LECS), and the LAN Emulation Server (LES).
Page 95
[Error Logging] Whether or not the BUS, LECS, and LES error logs are enabled. [Min TD Negotiation] Whether or not minimum acceptable traffic descriptor negotiation is enabled. Value/Field Size Default All, Proxy Proxy SmartSwitch ATM Switch Reference Manual 2-67 ELAN...
Page 96
2-68 SmartSwitch ATM Switch Reference Manual Console Commands Description Quickly configures an ELAN on the switch. It adds an ELAN entry in the databases for the BUS, LECS, and LES. It also activates the ELAN. Quickly removes an ELAN configuration from the switch.
Page 97
ELAN Type : 802.3 : 1516 Connection Method : SVC Distribute VPI/VCI: 0/0 Distribute Method : PROXY Multipoint : YES Error Logging : NO Min TD Negotiation : NO switch_prompt # : 11 SmartSwitch ATM Switch Reference Manual 2-69 ELAN...
VLAN : 0 ------------------------------------ McastId Group MAC Address : 01:80:C2:00:00:00 Distribute VPI/VCI : 0/62 switch_prompt # 2-70 SmartSwitch ATM Switch Reference Manual Console Commands Value/Field Size 0-125 Description Displays multicast group MAC addresses served by an ELAN. Default No default...
# switch_1 # show eventdisplay Event Display is OFF switch_1 # Value/Field Size On, Off Description Toggles display of event messages on the console screen. Displays status of events display. : off SmartSwitch ATM Switch Reference Manual 2-71 EventDisplay Default...
Deletes an event or all events. Displays event(s) currently logged. Event information includes message index number, event ID, message text, severity, and a timestamp (time the event occurred, with respect to switch up-time in hours, minutes, seconds, and milliseconds). Console Commands...
Page 101
Sendto failed for IP address 206.61.231.153 33554656 MINOR EVENT --------------------------------------------------- Sendto failed for IP address 206.61.231.153 33554656 MINOR EVENT --------------------------------------------------- Sendto failed for IP address 206.61.231.153 001:27:50:708 001:27:51:612 001:27:51:728 001:27:53:683 001:27:50:708 001:27:51:612 001:27:53:683 SmartSwitch ATM Switch Reference Manual 2-73 Events...
Exit Exit Use Exit to disconnect your console connection from the switch. Operator exit Parameters This attribute has no parameters. Just enter Descriptions Operator Permission [exit] <exit> exit Examples switch_prompt # exit Exiting SmartSwitch Command Console 2-74 SmartSwitch ATM Switch Reference Manual at the switch prompt.
Description Updates the switch software (for example, when upgrading your switch). You must know the full pathname of the updated image files. In addition, the TFTP protocol must be installed on the server. After doing an update, you must reboot the switch for the new firmware to take effect.
Page 104
Using TFTP to get and program bootfile builds/lab-02.02.22/server.i ma from 206.61.237.127. 4903K (5021184 bytes) received. Flash update succeeded. You will have to reboot for the new image to take effect. switch_prompt # 2-76 SmartSwitch ATM Switch Reference Manual : 206.61.237.127 : builds/lab-02.02.22/ser Console Commands...
To repeat a command listed by history, type !<indexnumber> in the following example, type SmartSwitch ATM Switch Reference Manual 2-77 History . For example, to repeat passwd...
The deletion occurs when the new module is plugged into the chassis backplane. Operators modify, show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. [IlmiAddressRegistration] Controls ILMI address registration. [IlmiConnectivity] Controls ILMI connectivity. [Timer-S] Timer S in seconds for establishing ILMI connectivity.
Page 107
(for example: Output Parameter Description [Port] Port number on the switch. (Same as the [PortNumber] input parameter.) [ILMIAddress] Shows whether or not ILMI address registration is enabled. [ILMI] Shows whether or not ILMI connectivity is enabled.
Console Commands IPAddress Use IPAddress to change IP addresses of the Ethernet port and IP netmask on the switch. Operators modify Parameters This attribute has no output parameters. Input Parameter Description [IPAddress] IP address of the Ethernet port. [IPNetMask] IP netmask of the Ethernet port. Defaults to the appropriate netmask, based on the class of the IP address.
IP to ATM addresses for destination clients on the VLAN. Operators show Parameters Input Parameter Description [ClientNumber] Number of the IP/ATM client on the switch that is the acting as the ARP server. Output Parameter Description [IP Address] IP address of the IP/ATM destination client . [ATM Address] ATM address of the IP/ATM destination client.
Console Commands IPATMClient Use IPATMClient to add or modify IP/ATM clients on the switch. Any of the clients can act as an ARP server. Use the Client attribute to delete, restart, or show IP/ATM clients. Note Operators add, modify Parameters This attribute has no output parameters.
Page 112
2-84 SmartSwitch ATM Switch Reference Manual Description Creates a new IP/ATM client on the switch. If the circuits in this VLAN are SVCs, and if you want to use this client as the ARP server, enter for the server type. If you do not...
IPATMPVC IPATMPVC Use IPATMPVC to manage IP/ATM PVCs. The following applies to the SmartSwitch 2500 family only: The Note command removes the specified IPATMPVC as well as the PVC ipatmpvc associated with it. Operators add, delete, show Parameters Input Parameter...
Page 115
# Description Removes the specified IP/ATM PVC. Displays the details of an IP/ATM PVC. : 1a1 : 130 : cpu : 130 High Type| Port VPCI Type | Status : 10.1.1.2 SmartSwitch ATM Switch Reference Manual 2-87 IPATMPVC | Admin...
LANEClient Use LANEClient to add or modify LANE clients on the switch. (Add a LANE client on the switch if you want to access the switch console using LANE.) Note Use the Client attribute to delete, restart, or show LANE clients.
Page 120
# 2-92 SmartSwitch ATM Switch Reference Manual Description Creates a new LANE client on the switch. Add a LANE client if you want to access the switch command console using LANE. Changes an existing LANE client on the switch.
Administrator Administrator stop lecs Note The status of the LECS is persistent on reboot. If you reboot the switch while you have the LECS stopped, it will remain stopped after rebooting.You have to manually start the LECS again. Examples switch_prompt # start lecs...
Address of the LES associated with the ELAN. [ELAN Type] The data-link type used by the ELAN. [MTU] Maximum transfer unit for the clients joining this ELAN. 2-96 SmartSwitch ATM Switch Reference Manual Value/Field Size Default 0-125 Up to 32 characters...
Page 125
BUS ATM address to assign to the ELAN (or if you want to change the ELAN type). Displays a specified ELAN configuration on the LECS. SmartSwitch ATM Switch Reference Manual 2-97 LECSELAN add lecselan add buselan, add show elan...
Page 126
TLVSet() switch_prompt # switch_prompt # show lecselan ELANNumber(ALL) All the ELANs Configured on the LECS ============================================================================ ELAN Number ELAN Name : elan1 LES Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:04 ELAN Type : 802.3 : 1516 switch_prompt # 2-98 SmartSwitch ATM Switch Reference Manual...
ATM address of the client. LECSELANLEC Value/Field Size Default 13-20 byte hex-based/ No default Up to 59 characters SegId: 0-4095 No default Bridge Num: 0-15 Dot decimal/ No default 7-15 characters 0-125 1-32767 No default SmartSwitch ATM Switch Reference Manual 2-99...
Page 128
Administrator show [ELANNumber] <elannumber> lecselanlec 2-100 SmartSwitch ATM Switch Reference Manual Description Maps a LANE client to a preferred ELAN and TLV set. The client must have unique IP, ATM, and MAC address for an entry to be accepted. You do not have to all addresses, but whatever you specify has to be unique.
Administrator delete [ELANNumber] <elannumber> [ELANName] <elanname> lecselannametable Administrator show lecselannametable 2-102 SmartSwitch ATM Switch Reference Manual Value/Field Size Default 0-125 Up to 32 characters No default Description Adds an entry to the ELAN name table. Deletes an entry from the ELAN name table.
Page 131
LECSELANNameTable Examples switch_prompt # show lecselannametable ELAN ID ELAN Name ============================================================================== ELAN1 switch_prompt # SmartSwitch ATM Switch Reference Manual 2-103...
LECSELANNameTable to manage entries in this table. Description Adds an entry to the ELAN policy table. Deletes an entry from the ELAN policy table. Modifies an entry in the ELAN policy table. Displays the ELAN policy table. SmartSwitch ATM Switch Reference Manual 2-105 LECSELANPolicy...
Page 134
Index Assignment Policy ============================================================================== Best Effort (Proprietary) By ATM Address By MAC Address By LAN Type By Packet Size switch_prompt # 2-106 SmartSwitch ATM Switch Reference Manual Priority Value 65001 2000 4000 5000 6000 : 3000 : 10 : 7000...
[ATM Address] ATM address of the client associated with the error. [ErrorCode] Decimal code that shows why the error occurred (see Table 2-5). [SysUpTime] Time the error occurred with respect to switch up-time in hours, seconds, minutes. ÊÊ Descriptions Operator Parameters/Permissions...
# delete lecserrorlog switch_prompt # switch_prompt # show lecserrorlog ATM Address ============================================================================== 39:00:00:00:00:00:00:00:00:00:14:17:80:00:20:d4:14:17:80 switch_prompt # 2-108 SmartSwitch ATM Switch Reference Manual Meaning The parameters given are incompatible with the ELAN. SOURCE-LAN-DESTINATION duplicates a previously-registered LAN destination. SOURCE-LAN-DESTINATION duplicates a previously-registered ATM address.
ErrorLogStatus(Disabled) switch_prompt # switch_prompt # show lecserrorlogcontrol Administrative Status : Disabled Operation Status : Disabled Clear Log Flag : No operation Log Max Entries : 128 Log Last Entry Index switch_prompt # 2-110 SmartSwitch ATM Switch Reference Manual : enable...
Use LECSNeighbor to add or delete LECS synchronization neighbors. The LECS neighbors are on other switches and communicate with the LECS on this switch (local LECS). The LECS neighbors provide the local LECS with information about LES servers attached directly to them. In turn, the local LECS provides its LECS neighbors with information about LES servers attached directly to it.
Use LECSNeighborInfo to display status information about LECS neighbors. The LECS neighbors are remote LECS servers that are known to (communicate with) the LECS on the switch (local LECS). The information includes the identity of each LECS neighbor, the VPI/VCI and state of the outgoing leaf connection to that neighbor (point-to-multipoint connection from the local LECS), and the VPI/VCI of the incoming VCC from the LECS neighbor to the local LECS.
LECSServerList LECSServerList Use LECSServerList to display the list of LES/BUS servers known to the LECS on the switch (local LECS). The information is sorted by ELAN number (according to ELANs supported by the LES/BUS servers). The LES/BUS servers can be known to the local LECS in either of two ways: The LES is attached directly to the local LECS and is sending configuration requests to it;...
Page 143
Alive Time (secs) : 29 Locally Attached : Yes Config Direct VCC : 2/93 Server ID : 0x0008 LECID Range : 0x2000 - 0x23FF switch_prompt # Description Shows LES servers known to the LECS. SmartSwitch ATM Switch Reference Manual 2-115 LECSServerList...
ELAN number to use for the packet size request. (Same as the [ELANNumber] input parameter.) [Packet Size] Packet size associated with the ELAN number. Descriptions Operator add lecspacketsizes delete lecspacketsizes 2-116 SmartSwitch ATM Switch Reference Manual Parameters/Permissions [ELANNumber] <elannumber> [PacketSize] <packetsize> Administrator [ELANNumber] <elannumber> [PacketSize] <packetsize> Administrator...
Page 145
# switch_prompt # show lecspacketsizes ELAN ID Packet Size ============================================================================== 0 (implies "unspecified") 1516 4544 9234 18190 switch_prompt # Parameters/Permissions Administrator : 1516 : 1516 SmartSwitch ATM Switch Reference Manual 2-117 LECSPacketSizes Description Displays entries in the packet size table.
Description Operator Parameters/Permissions show lecstat 2-118 SmartSwitch ATM Switch Reference Manual Description Number of successful configuration requests. Number of bad configuration requests. Number of configuration requests with invalid request parameters. Number of configuration requests LECS could not process due to insufficient resources.
[Max Unknown Frame Time]. That is why [Max Unknown Frame Time] appears in lecstlvset when “2” is entered at the [TLVIndex] prompt. lecstlvparam 2-120 SmartSwitch ATM Switch Reference Manual Value/Field Size 1-32767 1-15 Description Removes a TLV parameter from a TLV set on the LECS.
Page 149
TLVSet 2 : Control Timeout Max Unknown Frame Time Arp Aging Time Forward Delay switch_prompt # switch_prompt # delete lecstlvparam TlvsetNumber() TlvIndex() TLVIndex TLVDescription ============================================================================ Max Unknown Frame Count Confirm(y/n)?:y switch_prompt # Value Value SmartSwitch ATM Switch Reference Manual 2-121 LECSTLVParam...
MAC address in its cache in the absence of updates. [ArpResponseTime] Maximum time that the LEC expects a request/response cycle to take. 2-122 SmartSwitch ATM Switch Reference Manual Value/Field Size Default 1-32767 10-300 seconds No default...
Page 151
MPC Initial Retry Time. LECSTLVSet Value/Field Size Default 1-4 seconds No default 1-8 seconds No default 0-4095 seconds No default No default 0-370370 cells/s No default 0-370370 cells/s No default 1-10 seconds No default SmartSwitch ATM Switch Reference Manual 2-123...
Page 152
[MPCSetupFrameCount] <mpcsetupframecount> [MPCSetupFrameTime] <mpcsetupframetime> [MPCFlowProtocols] <mpcflowprotocols> [MPCRetryTime] <mpcretrytime> [MPCMaxRetryTime] <mpcmaxretrytime> Administrator delete [TLVSetNumber] <tlvsetnumber> lecstlvset Administrator 2-124 SmartSwitch ATM Switch Reference Manual Value/Field Size Default Description Creates a TLV set on the LECS. Removes a TLV set from the LECS.
Page 153
[MPSDefaultHoldingTime] <mpsdefaultholdingtime> [MPCSetupFrameCount] <mpcsetupframecount> [MPCSetupFrameTime] <mpcsetupframetime> [MPCFlowProtocols] <mpcflowprotocols> [MPCRetryTime] <mpcretrytime> [MPCMaxRetryTime] <mpcmaxretrytime> Administrator show [TLVSetNumber] <tlvsetnumber> lecstlvset LECSTLVSet Description Changes an existing TLV set on the LECS. Displays a TLV set on the LECS. SmartSwitch ATM Switch Reference Manual 2-125...
Page 155
VCC Timeout Max Retry Count Arp Aging Time Forward Delay ARP Response Time Flush Timeout Path Switching Delay Local Seg Id Multicast Send VCC Type Connection Complete Time switch_prompt # Value 40000 2500 SmartSwitch ATM Switch Reference Manual 2-127 LECSTLVSet...
Operator Parameters/Permissions show [VC Type] <vctype> lecsvcc [VPI/VCI] <vpi/vci> Examples switch_prompt # show lecsvcc VC Type VPI/VCI =========================================== 0/31 0/33 0/112 switch_prompt # 2-128 SmartSwitch ATM Switch Reference Manual Descriptions Displays the active VCCs (SVCs and PVCs) on the LECS.
# NOTICE - 'ZLESSRV' LES sendjoinresp: at the switch prompt. start les stop les Description Shows LES and BUS status. Starts the LES and BUS on the switch. Stops the LES and BUS on the switch. SmartSwitch ATM Switch Reference Manual 2-129...
[LECId] <lecidvalue> Administrator show [Elan Number] <elannumber> lesclient Value/Field Size 0-125 1-65279 Description Removes a client from the specified ELAN. Displays information about all clients that have joined the specified ELAN. SmartSwitch ATM Switch Reference Manual 2-131 LESClient Default...
Up to 32 characters PVC, SVC 802.3 (Ethernet) 802.3 802.5 (Token Ring) Yes: VCC is PMP No: VCC is PTP 1516, 1580, 4544, or 1516 9234 Yes, No Yes, No Positive integer Positive integer SmartSwitch ATM Switch Reference Manual 2-133 LESELAN...
Page 162
[BUSATMAddress] <busatmaddress> Administrator delete [ELANNumber] <elannumber> leselan Administrator 2-134 SmartSwitch ATM Switch Reference Manual Value/Field Size All, Proxy 13-20 byte hex-based/ Up to 59 characters Description Creates a specified ELAN on the LES. Each ELAN must have both an LES and a BUS assigned to it.
Page 163
ATM Address : 39:00:00:00:00:00:00:11:22:33:44:55:66:00:20:D4:14:15:0B:02 Confirm(y/n)? switch_prompt # Description Modifies parameters on the specified ELAN of the LES by deleting and then recreating the ELAN. Displays which ELANs are currently on the LES. : 102 SmartSwitch ATM Switch Reference Manual 2-135 LESELAN...
Page 164
: 9234 Connection Method : SVC Distribute VPI/VCI : 0/0 Distribute Method : PROXY ELAN Type : 802.3 Multipoint : YES Error Logging : NO Min TD Negotiation : NO BUS Address : 39:00:00:00:00:00:00:00:20:D4:14:15:00:00:20:D4:14:15:66:02 2-136 SmartSwitch ATM Switch Reference Manual :102...
[ATM Address] ATM address associated with the error. [ErrorCode] Decimal code that indicates why the error occurred (See Table 2-7). [SysUpTime] Time the error occurred with respect to switch up-time in hours, minutes, and seconds. Descriptions Operator Parameters/Permissions delete leserrorlog [ELANNumber] <elannumber>...
Invalid ATM address No configuration LE_CONFIGURE Error Insufficient information TLV not found 2-138 SmartSwitch ATM Switch Reference Manual Meaning Successful Response VERSION field of request contains a value higher than that supported. The parameters given are incompatible with the ELAN.
Page 167
# show leserrorlog ELANNumber(ALL) Error Log Entries for VLAN : 1 ATM Address 39:1:2:3:4:5:6:7:8:9:0:1:2:3:4:5:6:7:8:9 switch prompt # clear leserrorlog ELANNumber(ALL) Clearing ALL LES ELAN ErrorLog Confirm(y/n)?:y switch prompt # ErrorCode SysUpTime 01:02:03 SmartSwitch ATM Switch Reference Manual 2-139 LESErrorLog...
Operator Parameters/Permissions show [ELANNumber] <elannumber> leslecstat [LECId] <lecid> 2-140 SmartSwitch ATM Switch Reference Manual Value/Field Size 0-125 Description Displays statistical information about LANE clients on a specific ELAN. To verify the LEC ID, enter show client first to obtain the ELAN number.
LECS (to get configuration information from that LECS). The LES is not necessarily on the same switch as the LECS to which it is directly attached. Each LES is colocated with a BUS. Though the LES and BUS are separate entities, the two together are considered an instance of LES/BUS servers.
Page 171
The VPI/VCI of the point-to-point connection to the neighbor for purposes of cache synchronization. Description Displays information on VCCs related to LES/BUS servers : 0/35 : 0/40 : 0/41 : Connected : 0/42 : 0/38 SmartSwitch ATM Switch Reference Manual 2-143 LESLNNIInfo...
[Broadcast Packets Forwarded] For individual neighbors, the following statistics are shown for packets received from that neighbor. [Neighbor Address] [ARP Requests Received] 2-144 SmartSwitch ATM Switch Reference Manual Value/Field Size 0-125 or All Description Number of ARP requests forwarded by all LES servers.
Page 173
Unicast packets received from the neighbor BUS. Multicast packets received from the neighbor BUS. Broadcast packets received from the neighbor BUS. Description Clears statistics for the specified ELAN. Displays statistics for the specified ELAN. SmartSwitch ATM Switch Reference Manual 2-145 LESLNNIStat...
Page 174
FLUSH Responses Received TOPOLOGY Requests Received : 0 Unicast Packets Received Multicast Packets Received : 0 Broadcast Packets Received : 12 switch_prompt # clear leslnnistat ELANNumber(ALL) Clear LES/BUS LNNI statistics for all ELANs Confirm(y/n)?:y switch_prompt # 2-146 SmartSwitch ATM Switch Reference Manual...
Duplicate ATM address errors for join request. Duplicate ATM address errors for register request. Insufficient resources to grant errors for join request. Insufficient resources to grant errors for register request. Access denied errors for join request. SmartSwitch ATM Switch Reference Manual 2-147 LESStat Default...
Page 176
[ELANNumber] <elannumber> lesstat clear [ELANNumber] <elannumber> lesstat Administrator 2-148 SmartSwitch ATM Switch Reference Manual Description Access denied errors for register request. Invalid LECID errors for join request. Invalid LECID errors for register request. Invalid LAN destination errors for join request.
Page 177
Join invalid LAN destination errors Reg. invalid LAN destination Join invalid ATM address errors Reg. invalid ATM address errors switch_prompt # switch_prompt # clear lesstat ELANNumber(ALL) Clear LES ELAN 3 Statistics Confirm(y/n)?: y switch_prompt # :102 errors SmartSwitch ATM Switch Reference Manual 2-149 LESStat...
LinkMonitorTimeout LinkMonitorTimeout Use LinkMonitorTimeout to set or show the link monitor timeout value for switch ports. The timeout value is the number of seconds a port waits without traffic before releasing all resources for connections to it. Operators modify, show...
LNNIInfo Use LNNIInfo to set or display LNNI parameters on the switch. LNNIInfo is one of two attributes that apply to general LNNI configuration (the other is LNNIStatus). Operators modify, show Parameters Input Parameter [LECSID] Output Parameter [LECS ID] Descriptions...
Page 180
LNNIInfo Examples switch_prompt # show lnniinfo LECS ID switch_prompt # modify lnniinfo LECSID(2) switch_prompt # show lnniinfo LECS ID 2-152 SmartSwitch ATM Switch Reference Manual...
LNNIStatus Use LNNIStatus to enable or disable LNNI support on the switch. In addition, use LNNIStatus to selectively enable or disable use of Server Cache Synchronization Protocol (SCSP) when LNNI is enabled. LNNIStatus is one of two attributes that apply to general LNNI configuration (the other is LNNIInfo).
Vœ““>˜`°Ê+œÀÍ0À>vvˆV+œ˜}iÃ͈œ˜Ê>••œÝÃÊßœÖÊÍœÊÃiÍÊvalues for minimum and maximum threshold (in number of cells) for a specified priority queue at a port. If the number of cells received by the switch on the specified priority queue exceeds the maximum threshold, the switch discards the cell.
MyNMAddr that matches its Ethernet address. However, MyNMAddr can be changed to an IP address that corresponds to a LANE or IP/ATM (IP over ATM) client on the switch. This allows the switch to be managed through an ATM interface.
Operators add, delete, show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. [NetPrefix] Net prefix within the ATM address. Last three bytes of the chassis MAC address Value/Field Size A1 to B4 (physical-2500 family), A1.n to B4.n (virtual-2500 family),...
Page 188
TSM is deleted. Before you insert a replacement TSM, you can display existing net prefix information using the option (for example: Output Parameter Description [Port #] Port number on the switch. (Same as the [PortNumber] input parameter.) [NetPrefix] Net prefix within the ATM address. Descriptions Operator Parameters/Permissions [PortNumber] <portnumber>...
Use NetworkClock to set or display the port used as the network clock source. Operators modify, show Parameters This attribute has no output parameters. Input Parameter Description [PortNumber] Physical port number on the switch. A1 to B4 (2500 family), Descriptions Operator Parameters/Permissions modify networkclock [PortNumber] <portnumber> Administrator show networkclock Administrator...
Password Changed Successfully switch_prompt # Value/Field Size 0-8 characters (0 is no password) 0-8 characters (0 is no password) Description Changes the password of the current or lower-privileged user. SmartSwitch ATM Switch Reference Manual 2-163 Passwd Default No default No default...
PnniInterface Use PnniInterface to set or display characteristics to configure a switch port for PNNI routing. Operators modify, show Parameters Input Parameter Description [PortNumber] Port number on the switch. You can specify a physical or virtual port. [AdmnWtCbr] Administrative weight for the constant bit rate (CBR) service category.
Page 194
[AdminWtRtVbr]<admnwtrtvbr> [AdminWtNrtVbr] <admnwtnrtvbr> [AdminWtABR] <admnwtabr> [AdminWtUBR] <adminwtubr> [AggregationToken] <aggregationtoken> [RccServCategory] <rccservcategory> Administrator Administrator show pnniinterface 2-166 SmartSwitch ATM Switch Reference Manual command displays the following additional fields. show pnniinterface Description Sets parameters for PNNI routing. Displays parameters for PNNI routing.
PnniLink PnniLink Use PnniLink to display characteristics of all PNNI links connected directly to the switch. The characteristics include operation of each link and the relationship between each link and the nodes it connects. Note Use PnniNetworkLink to display links not connected directly to the switch but known to the switch through the exchange of database information.
Page 197
[Upnode ATM Addr] ATM address of the upnode. [Common Peer Group Id] Peer group ID shared by the local node (on switch) and upnode. [SVCC RCC Index] Index of switched virtual channel connection of routing control channel on link. [Rcv Hellos] Number of Hello packets received over the link.
Page 198
Upnode ATM Addr : NULL Common Peer Group Id: NULL SVCC RCC Index Rcv Hellos : 15953 Xmt Hellos : 15980 2-170 SmartSwitch ATM Switch Reference Manual Hello State Link Type 2WayInside Lowest Level Horizontal Link CommonOut Outside and Uplink CommonOut...
PnniMetrics Use PnniMetrics to manage PNNI metrics that apply to a logical node on the switch. Operators add, delete, show Parameters Input Parameter Description [MetricsTag] Number associated with a group of traffic parameters. [TrafficDirection] Direction in which the parameters apply.
Page 200
Indicates whether advertised GCAC parameters apply for CLP=0 traffic or for CLP=0+1 traffic. [Admin Wt] Administrative weight for the specified service categories from the switch to the remote end of the PNNI link. [Service Categories] Service category to which the parameters apply.
Page 201
[VarianceFactor] <variancefactor> Administrator delete [MetricsTag] <metricstag> pnnimetrics [TrafficDirection] <trafficdirection> [MetricsIndex] <index> Administrator Administrator show pnnimetrics (-8) for the specified service category. Description Creates a PNNI metric. Deletes a PNNI metric. Displays PNNI metrics. SmartSwitch ATM Switch Reference Manual 2-173 PnniMetrics...
Page 202
: Not used Cell Rate Margin : Not used Variance Factor : Not used switch_prompt # switch_prompt # delete pnnimetrics MetricsTag(1) TrafficDirection(Outgoing) MetricsIndex(1) 2-174 SmartSwitch ATM Switch Reference Manual Admin Wt Service Categories CLP0+1 5040 CLP0+1 5040 CLP0+1 5040 CLP0...
Page 203
: Not used Cell Loss Ratio CLP0 : Not used Cell Loss Ratio CLP0+1 : Not used Cell Rate Margin : Not used Variance Factor : Not used The metrics was deleted successfully. switch_prompt # PnniMetrics SmartSwitch ATM Switch Reference Manual 2-175...
PnniNeighbor PnniNeighbor Use PnniNeighbor to display PNNI neighbors of any logical node on the switch. The PNNI neighbors are themselves logical nodes on other switches. Each PNNI neighbor is linked directly to one of the local logical nodes. (The logical nodes on the switch are viewed as local logical nodes.) PnniNeighbor displays node ID and database exchange...
Page 205
Parameters / Permissions show pnnineighbor [Num] <num> Administrator Description Displays the PNNI neighbor(s) of the switch. You might have configured multiple logical nodes on the switch, each having a different set of neighbors. SmartSwitch ATM Switch Reference Manual 2-177 PnniNeighbor...
Page 206
Rcv Ptsps Xmt Ptsps Rcv Ptse Reqs Xmt Ptse Reqs Rcv Ptse Acks Xmt Ptse Acks Port Count More(<space>/q)?: Ports connected the neighbor: Port Number Used for Flooding ================================= switch_prompt # 2-178 SmartSwitch ATM Switch Reference Manual Neighbor Node Id State...
PnniNetworkLink Use PnniNetworkLink to display characteristics of the PNNI hierarchy as seen from a logical node on the switch. The characteristics include the operation of all links and nodes known to the logical node through the exchange of database information. The logical node on the switch is viewed as the local node.
Page 208
Integer that associates a set of traffic parameters with this link. Descriptions Operator Parameters / Permissions show [Num] <num> pnninetworklink Administrator 2-180 SmartSwitch ATM Switch Reference Manual Description Displays information on the link(s) within the PNNI hierarchy as seen from the local logical node.
Page 209
Aggr Token Remote Node Id: 50:a0:39:00:00:00:00:00:00:00:00:00:28:c1:80:00:20:d4:28:c1:ff:0 Remote Port Id: 57344 Vp Capability : False Ptse Id Metrics Tag : 1118495 switch_prompt # Orig Port Id Remote Port Id SmartSwitch ATM Switch Reference Manual 2-181 PnniNetworkLink 4096 45056 16384 57344 45056 4096...
PnniNetworkNode Use PnniNetworkNode to display all nodes within the PNNI hierarchy as seen from a logical node on the switch. The logical node on the switch is viewed as the local node. The other nodes are viewed as remote nodes.
Page 211
If the remote node is not leader of its peer group, this parameter is set to NULL. Descriptions Operator Parameters / Permissions [Num] <num> show pnninetworknode Administrator Description Displays nodes within the PNNI hierarchy. SmartSwitch ATM Switch Reference Manual 2-183 PnniNetworkNode...
PnniNode Use PnniNode to set or display logical nodes on the switch. If the switch is represented on multiple levels of the PNNI hierarchy, it has a separate logical node (and node ID) for each representation. Operators add, delete, modify, show...
Page 214
Output Parameter Description [Rst Transit] Whether or not the switch is restricted to not allowing support of SVCs transiting it. Possible values are: True and False. [Complex Rep.] Whether or not the switch uses the complex node representation. Possible values are: True and False.
Page 215
Admin Status : UP Oper Status : UP ATM Address : 39:00:00:00:00:00:00:00:00:01:28:de:80:00:20:d4:28:de:ff:00 Peer Group Id: 50:39:00:00:00:00:00:00:00:00:01:00:00:00 Rst Transit : FALSE Complex Rep : FALSE Rst Branching: FALSE DB Overload : FALSE Ptse : 23 switch_prompt # SmartSwitch ATM Switch Reference Manual 2-187 PnniNode...
[NodeIndex] Identifier for a logical node on the switch. [PtseHolddown] Initial value for the PTSE holddown timer to limit the rate at which the switch can re-originate PTSEs. [HelloHolddown] Initial value for the Hello holddown timer that limits the rate at which the switch sends Hellos.
Page 217
[Node Index] Identifier for a logical node on the switch. [Ptse Holddown] Initial value for the PTSE holddown timer to limit the rate at which the switch can re-originate PTSEs. [Hello Holddown] Initial value for the Hello holddown timer that limits the rate at which the switch sends Hellos.
PnniPeerGroupId PnniPeerGroupId Use PnniPeerGroupId to set the peer group ID of a logical node on the switch. Operators modify Parameters This attribute has no output parameters. Input Parameter Description [NodeIndex] Identifier for a logical node on the switch. [PeerGroupId] The ID of the peer group of which this node is to become a member.
PnniPglElection Use PnniPglElection to set or display PNNI peer group election characteristics for the switch. The characteristics are with respect to a specific logical node on the switch (identified by the NodeIndex input parameter). Operators modify, show Parameters Input Parameter...
Page 222
Time at which the current PGL established itself. [Election State] Indicates the state that the switch is in with respect to the PGL election that takes place in the peer group. Possible values are: Starting, Awaiting, Awaiting Full, Initial Delay, Calculating, Await Unanimity, Operating as PGL, Operating not as PGL, Hung Election, and Waiting Reelection.
Page 223
Peer Group Leader : 50:a0:39:00:00:00:00:00:00:00:00:00:28:de:80:00:20:d4:28:de:ff:00 Active Parent Node Id : 48:50:39:00:00:00:00:00:00:00:00:00:00:00:00:00:20:d4:28:de:ff:00 switch_prompt # Description Sets PNNI election parameters for the switch. Displays PNNI election parameters for the switch. : 20 : 35 : 20 SmartSwitch ATM Switch Reference Manual 2-195 PnniPglElection...
PnniPtse PnniPtse Use PnniPtse to display PTSEs stored in the topology database of the switch. Operators show Parameters Input Parameter Description [Num] Index number assigned by the console that indicates which node originating the PTSE is displayed. Use the command to get a list of index numbers.
Page 225
Node Id : 50:a0:39:00:00:00:00:00:00:00:00:00:14:4a:00:00:20:d4:14:4a:00:00 Type Description PTSE Id ================================================================================ Nodal information Horizontal links Exterior address switch_prompt # Description Displays PTSEs in topology database of switch. Seq No. Checksum Lifetime 22746 23862 99 secs 50355 337 secs SmartSwitch ATM Switch Reference Manual 2-197...
PnniReachableAddress PnniReachableAddress Use PnniReachableAddress to display a list of reachable addresseses from the switch. The addresses are advertised by remote logical nodes that are visible to the switch (logical nodes from which the switch receives database information). Operators show Parameters...
Page 227
Adver. Node Id: 48:50:39:00:00:00:00:00:00:00:00:00:00:00:00:00:20:d4:14:41:ff:0 Adver. Port Id: 0 Address Index : 6 ATM Address : 39:00:00:00:00:00:00:00:00:00:28:e6:00:00:00:00:00:00:00 Prefix Length : 104 switch_prompt # Description Displays information on all reachable addresses from each node visible to the switch. SmartSwitch ATM Switch Reference Manual 2-199 PnniReachableAddress...
PnniScopeMapping PnniScopeMapping Use PnniScopeMapping to set or display the mappings of membership and connection scope from UNI to PNNI terms. The mappings are from the perspective of a logical node on the switch. Operators modify, show Parameters Input Parameter Description [NodeIndex] Identifier for a logical node on the switch.
Page 229
PNNI routing level) that lies within the UNI scope value global(15). Output Parameter Description [Node Index] Identifier for a logical node on the switch. [Local Network] Highest level of PNNI hierarchy (smallest PNNI routing level) that lies within the UNI scope value localNetwork(1). [Local Network Plus One] Highest level of PNNI hierarchy (smallest PNNI routing level) that lies within the UNI scope value localNetworkPlusOne(2).
Page 230
Highest level of PNNI hierarchy (smallest PNNI routing level) that lies within the UNI scope value interRegional(14). [Global] Highest level of PNNI hierarchy (smallest PNNI routing level) that lies within the UNI scope value global(15). 2-202 SmartSwitch ATM Switch Reference Manual...
Page 231
[CommunityPlusOne] <communityplusone> [Regional] <regional> [Global] <global> Administrator Administrator show pnniscopemapping <nodeindex> SmartSwitch ATM Switch Reference Manual 2-203 PnniScopeMapping Description Sets mappings of membership and organizational scope between UNI and PNNI. Displays mappings of membership and organizational scope between UNI and PNNI.
Page 232
Intra Organization Organization Plus One Community Minus One Intra Community Community Plus One Regional Inter Regional Global switch_prompt # 2-204 SmartSwitch ATM Switch Reference Manual : 96 : 96 : 96 : 80 : 80 : 72 : 72 : 64...
Number of connection setup messages including DTL stacks originated by the switch that have cranked back to the at all levels of the hierarchy. Number of alternate DTL stacks that the switch has computed and placed into signalling messages as the DTLOriginator.
Use PnniSummaryAddress to manage summary address prefixes for the switch. A summary address is an abbreviation of a set of addresses, represented by an address prefix that all of the summarized addresses have in common. The switch advertises this information. Calls to any destinations matching the summary address may be routed to the switch.
Page 236
Identifier of a logical node on the switch. [Prefix Length] Prefix length for the summary. [State] Whether or not the summary is currently being advertised by the switch to peer group. Possible values are: Active, Advertised, or Inactive. Descriptions Operator Parameters / Permissions [NodeIndex] <nodeindex>...
PnniSvccRcc PnniSvccRcc Use PnniSvccRcc to display status of the switched virtual channel connection (SVCC) used by the routing control channel (RCC) of a logical node on the switch. Operators show Parameters Input Parameter Description [NodeIndex] Identifier of a logical node on the switch.
Page 239
Examples switch_prompt # show pnnisvccrcc NodeIndex(2) SvccRccIndex(ALL) Svcc Rcc Index Port ================================================================================ switch_prompt # Rcv Hellos Xmt Hellos Hello State 113472 113534 2WayInside SmartSwitch ATM Switch Reference Manual 2-211 PnniSvccRcc...
PnniTnsRoute PnniTnsRoute Use PnniTnsRoute to manage routes to transit networks that are visible to the switch. Operators add, delete, show Parameters Input Parameter Description [Num] Index number of the route as assigned by the console. Use the show pnnitnsroute all to get a list of index numbers.
Page 241
0…iÊÜ>•ÖiÊœvÊÍ…iÊÀi“>ˆ˜ˆ˜}Ê•ˆvi͈“iÊvœÀÊÍ…iÊ}ˆÜi˜Ê+0..Ê>ÃʈÍÊ>««i>ÀÃʈ˜ÊÍ…iÊ•œV>•ÊÍœ«œ•œ}ßÊ `>Í>L>Ãi°Ê.Þ«ÀiÃÃi`ʈ˜ÊÃiVœ˜`ð Q-œÖÍiÊ0ß«iR 0ß«iÊœvÊÀi>V…>Lˆ•ˆÍßÊvÀœ“ÊÍ…iÊÃ݈ÍV…ÊÍœÊÍ…iÊÍÀ>˜ÃˆÍʘiÍÝœÀްÊ+œÃÈL•iÊÜ>•ÖiÃÊ>Ài\Ê.ÞÍiÀˆœÀÊ>˜`Ê #Í…iÀ° Q+ÀœÍœVœ•R -œÖ͈˜}Ê“iV…>˜ˆÃ“ÊÖÃi`ÊÍœÊ`iÍiÀ“ˆ˜iÊVœ˜˜iV͈܈ÍßÊLiÍÝii˜ÊÍ…iÊÃ݈ÍV…Ê>˜`ÊÍ…iÊÀi>V…>L•iÊ >``ÀiÃÃÊ«ÀivˆÞ°ÊÊ+œÃÈL•iÊÜ>•ÖiÃÊ>Ài\Ê#Í…iÀ]Ê>œV>•]Ê }“Í]Ê>˜`Ê+!!7° Q.Vœ«iR +!!7ÊÃVœ«iÊœvÊ>`ÜiÀ͈Ãi“i˜ÍÊ-•iÜi•ÊœvÊ+!!7Ê…ˆiÀ>ÀV…ß®ÊvÀœ“ÊÍ…iÊÃ݈ÍV…ÊÍœÊÍ…iÊÀœÖÍi° Q7«Ê+>«°R 8…iÍ…iÀÊœÀʘœÍÊ7++ÃÊV>˜ÊLiÊiÃÍ>L•ˆÃ…i`ÊvÀœ“ÊÍ…iÊ>`ÜiÀ͈Ș}ʘœ`iÊÍœÊÍ…iÊÍÀ>˜ÃˆÍʘiÍÝœÀް Q iÍÀˆVÃÊ0>}R Metrics tag assigned to the connection with the transit network. Q+0..Ê7`R 4œÀÊÀi>V…>L•iÊ>``ÀiÃÃiÃÊ•i>À˜i`ÊÍ…ÀœÖ}…Ê+!!7]ÊÍ…ˆÃÊ«>À>“iÍiÀÊVœ˜Í>ˆ˜ÃÊÍ…iÊÜ>•ÖiÊœvÊÍ…iÊ +0..ʈ`i˜ÍˆvˆiÀÊvœÀÊÍ…iÊ+0..ÊÍ…>ÍʈÃÊœÀˆ}ˆ˜>Íi`ÊLßÊÍ…iÊœÀˆ}ˆ˜>͈˜}ʘœ`iÊ>˜`ÊVœ˜Í>ˆ˜ÃÊÍ…iÊ ˆ˜vœÀ“>͈œ˜Ê}ÀœÖ«-îÊ`iÃVÀˆLˆ˜}ÊÍ…iÊÀi>V…>L•iÊ>``ÀiÃðÊÊ4œÀÊÀi>V…>L•iÊ>``ÀiÃÃiÃÊ•i>À˜i`ÊLßÊ “i>˜ÃʜͅiÀÊÍ…>˜Ê+!!7]ÊÍ…ˆÃÊ«>À>“iÍiÀʈÃÊÃiÍÊÍœÊãiÀœ° Q#«iÀÊ.Í>ÍÖÃR 8…iÍ…iÀÊœÀʘœÍÊÍ…iÊÀi>V…>L•iÊ>``ÀiÃÃÊ«ÀivˆÞʈÃÊœ«iÀ>͈œ˜>••ßÊÜ>•ˆ`Ê>˜`ÊÝ…iÍ…iÀʈÍʈÃÊ>`ÜiÀ† ͈Ãi`ÊLßÊÍ…ˆÃʘœ`i°ÊÊ+œÃÈL•iÊÜ>•ÖiÃÊ>Ài\Ê"`ÜiÀ͈Ãi`]Ê"V͈Üi]Ê>˜`Ê7˜>V͈Üi° PnniTnsRoute SmartSwitch ATM Switch Reference Manual 2-213...
Page 242
[Index] <index> Administrator Examples switch_prompt # add pnnitnsroute PortNumber() TnsType(NationalNetworkId) TnsPlan(CarrierIdCode) TnsId() Index(0) RouteType(Exterior) PnniScope(0) MetricsTag(0) 2-214 SmartSwitch ATM Switch Reference Manual Description Adds a TNS route from the switch. Deletes a TNS route from the switch. : 1A2 : 90:00:00:01...
Page 243
# switch_prompt # show pnnitnsroute Num(ALL) Num Port TNS Type ================================================================================ NationalNetworkId CarrierIdCode 90:00:00:01 NationalNetworkId CarrierIdCode 90:00:00:01 switch_1 # : 39:00:00:01 TNS Plan TNS Id TNS Index 4369 E SmartSwitch ATM Switch Reference Manual 2-215 PnniTnsRoute Type Proto MGMT PNNI...
Port Use Port to add or delete a virtual port on the switch. The following applies to SmartSwitch 6500 only: You can hot-swap TSMs. Note Hot-swapping is replacing a module when the chassis is powered up. If you replace a TSM with another TSM of the same type (same I/O ports), existing configuration of port parameters is not affected.
Page 245
Value/Field Size Default No default 6-12 No default (MaxVpiBits) No default (MaxVciBits ) 32-[2 No default (MaxVpiBits+ MaxVciBits) No default Positive integer No default Description Adds a virtual port. Deletes a virtual port. SmartSwitch ATM Switch Reference Manual 2-217 Port...
PortClockMode Use PortClockMode to set the clock mode of a switch port. Operators modify, show Parameters Input Parameter Description [PortNumber] Port number on the switch. [PortClkMode] Clocking mode (see Table 2-8). Output Parameter Description [Port Number] Physical port number on the switch.
Page 248
Description Loop Port clock is set to looped timing. Local Port clock is set to split timing using the local clock on the switch. Network Port clock is set to split timing using the network clock of the switch. Examples...
PortConfig Use PortConfig to manage configuration of switch ports. The following applies to SmartSwitch 6500 only: You can hot-swap TSMs. Note Hot-swapping is replacing a module when the chassis is powered up. If you replace a TSM with another TSM of the same type (same I/O ports), existing configuration of port parameters is not affected.
Page 250
(detailed) command. The display shows both current and configured state of the parameters. Output Parameter Description [Port Name] Port number on the switch. (Same as the [PortNumber] input parameter.) [Intf Type] Interface type. (Same as the [InterfaceType] input parameter.) [Sig Type] Type of signaling on the port.
Page 252
Max Svp Vpci Max Vpcs ILMI State Admin State up Port State Admin State down Oper State down Port Bandwidth Max 155.0 switch_prompt # 2-224 SmartSwitch ATM Switch Reference Manual Trans Media Used Type Type Bw(MBS) Bw(MBS) State 155.0 10.50 10.50...
All 15-characters maximum Description Port number on the switch that specifies the incoming port. Port number on the switch that specfies the outgoing port. Name of the ATM filter set. Number of calls that were acted on by this filter set that have passed through.
Page 254
InComingPort OutGoingPort FilterSetName ============================================================================== SET1 switch_prompt # 2-226 SmartSwitch ATM Switch Reference Manual Description Adds an ATM filter set to a pair of incoming and outgoing ports. Deletes an ATM filter set from a pair of incoming and outgoing ports.
PortMode Use PortMode to manage transmission characteristics of switch ports. See Table 2-9 for supported I/O modules (and corresponding port types). Note Operators modify, show Parameters In the parameter tables below, text in parenthesis indicates parameters that appear only for particular port types. For...
Page 256
225 feet. LT225 means the cable is less than 255 feet. [Timing] Enables or disables timing at the port. Timing can improve speed matching and (622 Mbps only) sequencing of transmissions between the switch and network. Descriptions Operator Parameters/Permissions modify [PortNumber]<portnumber>...
Page 258
# NOTICE - 'tZLinkStatus' Port 2B2 (6) UP switch_prompt # show portmode 1b2 Port Type Mode Framing ============================================================================== PLCP CCHANNEL switch_prompt # 2-230 SmartSwitch ATM Switch Reference Manual Trans Media Used Type Type Bw(MBS) Bw(MBS) State STS-3c CAT5 UTP 155.0...
Description Same as [PortNumber] input parameter. Total OAM (operations and maintenance) cells the system received. Total cells dropped when the switch drops cells (includes those dropped when unknown VCs (virtual circuits) and CLP1 (cell loss priority) cells are dropped). Total cells dropped across the system. (includes those dropped when unknown VCs (virtual circuits) and CLP1 (cell loss priority) cells are dropped).
Page 260
[PortNumber] <portnumber> portstat clear [PortNumber] <portnumber> portstat 2-232 SmartSwitch ATM Switch Reference Manual Descriptions Displays ATM statistics for a given port or all ports, represented in number of cells. These statistics relate to network resources management, congestion, and performance issues. The counter has a 32-bit maximum before it wraps around.
Page 261
Total Cells Dropped OAM Cells Received RM Cells Received CLP1 Cells Received Unknown VC Cells Dropped CLP1 Cells Dropped Total Cells Dropped Unk VC CLP1 Total Dropped Dropped Dropped 13839 13839 : 13851 : 13851 SmartSwitch ATM Switch Reference Manual 2-233 PortStat...
Page 262
CLP1 Cells Dropped Total Cells Dropped CPU Statistics ============================================================================ OAM Cells Received RM Cells Received CLP1 Cells Received Unknown VC Cells Dropped CLP1 Cells Dropped Total Cells Dropped switch_prompt # 2-234 SmartSwitch ATM Switch Reference Manual : 16777215 : 16777215...
Use PortTrafficCongestion to manage traffic congestion at switch ports. You can program the values for the minimum and maximum threshold (in number of cells) for a specified priority queue. If the number of cells received by the switch on the specified priority queue for a port exceeds the maximum threshold, the switch discards the cell.
Page 264
[MinIndexNumber] <minindexnumber> [MaxIndexNumber] <maxindexnumber> Administrator show [PortNumber] <portnumber> porttrafficcongestion 2-236 SmartSwitch ATM Switch Reference Manual Description Sets traffic congestion parameters for a specified port. You can change the minimum and maximum buffer thresholds (in cells) for each priority queue. Cell...
Administrator and Read Only. Raises the privilege level. There are two levels in the switch—Read-Only and Administrator. If you are logged on with a Read-Only privilege status and then issue this command, the switch prompts you for the Administrator [Password] before allowing access to Administrator commands.
Prompt Use Prompt to control how the switch prompt is displayed on the console monitor. Operators modify Parameters This attribute has no output parameters. Input Parameter Description [Prompt] New prompt name. Descriptions Operator Parameters/Permissions modify [Prompt] <newpromptname> prompt Administrator Example...
Use PVC to manage PVCs on the switch. You assign two physical or virtual ports on the switch as PVC endpoints. When you add the PVC, the endpoints are called Port 1 and Port 2 (corresponding Note to order of entry). For subsequent action on the PVC (activate, deactivate, show, delete), the endpoints are called High Port and Low Port.
Page 269
Positive integer A1 to B4 (physical-2500 family), A1.n to B4.n (virtual-2500 family), 1A1 to 8B4 (physical-6500), 1A1.n to 8B4.n (virtual-6500) Positive integer Positive integer SmartSwitch ATM Switch Reference Manual 2-241 Default No default No default No default No default No default...
Page 270
Positive integer Description Cross-connect ID of the PVC (as assigned by switch software). Each PTP PVC has a unique cross-connect ID. PMP PVCs might have the same cross-connect ID but different cross-connect sub IDs.
Page 271
Operational status of high-to-low connection. Possible values are: Up or Down. Operational status of port. Time the PVC was created (relative to the switch boot time). Traffic type in the high-to-low direction. Early packet discard as calculated by CAC for the cross connect in the high-to-low direction .
Page 272
[Port2-to-Port1TrafficDescriptorIndex] <port2toport1trafficdescriptorindex> Administrator Administrator clear pvc 2-244 SmartSwitch ATM Switch Reference Manual Description Cell loss ratio in the low-to-high direction. Cumulative cell delay variation in the low-to-high direction. Maximum cell transfer delay in the low-to-high direction. Cumulative cell transfer delay in the low-to-high direction.
Page 273
[HighPortID] <highportnumber> [LowVPCI] <lowvpci> [HighVCI] <highvci> Administrator show pvc [PortNumber] <portnumber> [CrossConnectID] <crossconnectid> [CrossConnectSubID] <crossconnectsubid> Administrator Description Deacrivates the specified PVC. Admin status is set to Down. Deletes the specified PVC. Displays the specified PVC. SmartSwitch ATM Switch Reference Manual 2-245...
Page 274
Cross Connect Sub Id Low Port Low Vpci Low Vci Low - High Traffic Desc Index High - Low Traffic Desc Index Low Connection Type 2-246 SmartSwitch ATM Switch Reference Manual High Type| Port VPCI Type | Status : 3a3 : 33...
Page 275
Total number of PVCs = 1 switch_prompt # : 7A3 : 16 : PTP : UP : UP : UP : Operational : 0:0:0 : CBR : DISABLED : 1178891 : CBR : DISABLED : 1178900 SmartSwitch ATM Switch Reference Manual 2-247...
PVCById PVCById Use PVCById to manage a PVC by its cross-connect ID. The following applies to SmartSwitch 2500 family only: You can not delete or Note deactivate a PVC if an IP/ATM client is attached to the PVC through the IPATMPVC attribute.
(SmartSwitch 6500 Only) Use PVP to manage PVPs on the switch. You assign two physical ports on the switch as PVP endpoints. When you add the PVP, the endpoints are called Port 1 and Port 2 (corresponding Note to order of entry). For subsequent action on the PVP (activate, deactivate, show, delete), the endpoints are called High Port and Low Port.
Page 279
A1 to B4 (physical-2500 family), A1.n to B4.n (virtual-2500 family), 1A1 to 8B4 (physical-6500), 1A1.n to 8B4.n (virtual-6500) Positive integer command to get a Positive integer SmartSwitch ATM Switch Reference Manual 2-251 Default No default No default No default No default No default...
Page 280
Operational status of high-to-low connection. Possible values are: Up or Down. Operational status of port. Time the PVP was created (relative to the switch boot time). Traffic type in the high-to-low direction. Early packet discard as calculated by CAC for the cross connect in the high-to-low direction.
Page 281
Cumulative cell delay variation in the low-to-high direction. Maximum cell transfer delay in the low-to-high direction. Cumulative cell transfer delay in the low-to-high direction. Number of cells received in the low-to-high direction. Number of cells dropped in the low-to-high direction. SmartSwitch ATM Switch Reference Manual 2-253...
Page 282
Administrator show pvp [PortNumber] <portnumber> [CrossConnectID] <crossconnectid> [CrossConnectSubID] <crossconnectsubid> Administrator 2-254 SmartSwitch ATM Switch Reference Manual Description Activates the PVP specified. Administrative status is set to Up. Adds the specified PVP. Deletes all PVPs. Deactivates the specified PVP. Admin status is set to Down.
Parameters This attribute has no output parameters. Input Parameter Description [CrossConnectId] Cross-connect ID of the PVP (as assigned by switch software). Use the list of cross-connect IDs. [CrossConnectSubId] Cross-connect sub-ID of the PVP (as assigned by switch software).
Note that certain switch conditions are persistent on reboot. For example, if the LECS is stopped before the reboot, it will also be stopped after the switch comes back up. Also be aware that if you enter from a telnet session, it breaks any connection reboot you have with the switch.
Use RedundancyConfigBackup to copy switch configuration to the slave TSM/CPU backup file specified by the RedundancyInfo attribute. If you use the same backup file for the slave and master TSM/CPU modules, you can use command to copy the current switch configuration to the slave backup file. If the name or the backup switch location of the files is different, however, you must use switch configuration with the slave backup file.
Typically, you would use the same backup file for the slave and master modules. If you do, you can use the command to copy the current switch configuration to the slave backup file. If the name or location of the files...
Page 289
Whatever file you choose as the slave TSM/CPU configuration file, the file must exist on the TFTP server and must be located within the directory. /tftpboot Displays the location of the slave TSM/CPU configuration file. : 206.61.237.16 : backup/slave.ztr SmartSwitch ATM Switch Reference Manual 2-261 RedundancyInfo...
If the slave does not receive five consecutive heartbeats, it assumes the master is not active and reboots the switch. If the master still is not alive after reboot, automatic CPU switchover occurs (the slave module becomes the master module and vice versa).
Examples switch_prompt # modify redundancyoff NOTICE - 'tConsole' Wait for synchronous message timed out Redundancy Is Disabled switch_prompt # at the switch prompt. modify redundancyoff Description Turns OFF support for automatic TSM/CPU redundancy. SmartSwitch ATM Switch Reference Manual 2-263 RedundancyOff...
RedundancyStatus RedundancyStatus (SmartSwitch 6500 Only) Use RedundancyStatus to display status of automatic TSM/CPU redundancy and CSM redundancy on the switch. Operators show Parameters This attribute has no input parameters. Just type Output Parameter Description [Admin Status] Administrative status of automatic TSM/CPU redundancy (whether or not automatic TSM/CPU redundancy has been set ON with the RedundancyOn attribute).
Page 293
: Present In Slot #7 Standby CPU : Present In Slot #8 Active CSM : Present In Slot #9 Standby CSM : Present In Slot #10 RedundancyStatus Description Shows redundancy status on the switch. SmartSwitch ATM Switch Reference Manual 2-265...
[Refcnt] Internal/debugging information. [Use] Number of times this route has been used to send a packet. [Interface] Interface used for forwarding packets on this route. 2-266 SmartSwitch ATM Switch Reference Manual Value/Field Size Default Dot decimal/ No default 7-15 characters...
Page 295
Removes an IP route from the switch configuration when it is not directly connected to the NMS. Displays IP routes used by the switch. The flag numbers shown in the flags column relate to the hexadecimal figures listed in the Output Parameter table above.
0 to 999 Description Sets the number of rows per page on the console display (by telling the switch how many lines your console supports). If you do not want screen breaks in the output, set the number of rows to "0."...
[ISR Int] Total interrupts received. [RQU Int] Receive queue underrun indicator since last up-time or clear. [RQA Int] Receive queue alert indicator since last up-time or clear. at the switch prompt. show sarstat SmartSwitch ATM Switch Reference Manual 2-269 SARStat...
Page 298
Number of packets dropped. Descriptions Operator Parameters/Permissions Administrator show sarstat 2-270 SmartSwitch ATM Switch Reference Manual Description Displays all levels of statistics for the SAR. AAL (ATM adaptation layer) commands act on the SAR of VCs (virtual circuits) and VC statistics.
TSM is deleted. Before you insert a replacement TSM, you can display existing service registry information using the operator with the show 2-272 SmartSwitch ATM Switch Reference Manual Value/Field Size A1 to B4 (2500 family), 1A1 to 8B4 (6500),...
Page 301
Output Parameter Description [Port] Port number on the switch. (Same as the [PortNumber] input parameter.) [Type] Type of service. Possible values are: ANS or LECS. [Index] Index identifying two services registered for the same port and having the same service type.
Shutdown Use Shutdown to shut down the switch to a state where it can be powered off. Shutdown stops all logging and synchronizes the file system. You must enter Operator shutdown Parameters This attribute has no parameters. Just enter Descriptions...
Number of set-up messages received. [Emit Setup Attempts] Number of set-up messages transmitted. [Detect Unavailable Routes] Number of SVC calls rejected by this switch because of unavailable IISP or UNI routes generated on other switches. !Ö“LiÀÊœvÊ.7+ÊV>••ÃÊÀi•iVÍi`ÊLßÊÍ…ˆÃÊÃ݈ÍV…ÊLiV>ÖÃiÊœvÊÖ˜>Ü>ˆ•>L•iÊ77.+ÊœÀÊ2!7Ê [Emit Unavailable Routes] ÀœÖÍiÃÊ}i˜iÀ>Íi`Êœ˜ÊÍ…ˆÃÊÃ݈ÍV…°...
Page 305
Number of requests (by the user) on other switches to release all resources associated with the circuit controlled by signaling. [Emit Restarts] Number of requests (by the user) on this switch to release all resources associated with the circuit controlled by signaling. [In Call Establishments] Number of successful incoming call set-ups.
A1 to B4 (physical-2500 family), A1.n to B4.n (virtual-2500 family), 1A1 to 8B4 (physical-6500), 1A1.n to 8B4.n (virtual-6500), or All +œÃÈL•iÊÜ>•ÖiÃÊ>Ài\Ê0Ïä£]0ÏäÏ]Ê 0ÏäÈ]0Ïän]Ê0Ïä™]Ê0Ï£ä]Ê0Ï£Ï]Ê0Ï£È]Ê 0Ï£Ç]Ê0ÏÔÔ]Ê0ÏÏ£]Ê0ÏÏÏ]Ê0Ï™Ç]0Ï™n]Ê 0Ï™™° Zero or positive integer Zero or positive integer SmartSwitch ATM Switch Reference Manual 2-279 SigTimer Default T303...
Page 308
SigTimer Output Parameter Description [phy_port_id] Port number on the switch. (Same as the [PortNumber] input parameter.) [duration] Timer value in milleseconds. (Same as the [Interval] input parameter.) [retries] Number of times the timer has to be restarted. (Same as the [Retries] input parameter.)
SlotConfig Use SlotConfig to display configuration of slots in the switch chassis (to see which slots are occupied by TSM or CSM modules). You also can get specific information about each module. Operators show Parameters Input Parameter Description [Slot] Slot number in the switch chassis.
Spvc Use Spvc to add, delete, or show soft PVCs (SPVCs) on the switch. An SPVC connects this switch (the source switch) to a switch across the ATM network (the target switch). Note Before adding an SPVC at this switch, you must configure the target address at the target switch.
Page 312
2-284 SmartSwitch ATM Switch Reference Manual appears next to parameters that are available only through the </d> Description Physical port number on the switch. (Same as the [PortNumber] input parameter.) VPI allocated to the SPVC source port. (Same as the [SourceVpi] input parameter.) VCI allocated to the SPVC source port.
Page 313
Type of traffic in the forward (source to target) direction. Type of traffic in the backward (target to source) direction. Index of the forward (source to target) traffic descriptor. Index of the backward (target to source) traffic descriptor. SmartSwitch ATM Switch Reference Manual 2-285 Spvc Description Adds an SPVC.
Call cleared due to change in PGL Bearer capability not authorized. Bearer capability not presently available. Service or option not available, unspecified. Bearer capability not implemented. Unsupported combination of traffic parameters. AAL parameters cannot be supported. 2-286 SmartSwitch ATM Switch Reference Manual...
Page 315
Mandatory information element is missing. Message type non-existent or not implemented. Information element non-existent or not implemented. Invalid information element contents. Message not compatible with call state. Recovery on timer expiry. Incorrect message length. Protocol error, unspecified. SmartSwitch ATM Switch Reference Manual 2-287 Spvc...
Page 316
Retry Limit Traffic Type (Forward) Traffic Type (Backward) Forward Traffic Descriptor Index Backward Traffic Descriptor Index : 2 Total number of SPVCs = 1 2-288 SmartSwitch ATM Switch Reference Manual : 5a2 :100 :101 : 11:11:11:11:11:11:11:11:11:11:11:11: : 5a2 : 100...
Page 317
Deleted SPVC successfully. switch_prompt # switch_prompt # show spvc PortNumber(ALL) SourceVpi(0) SourceVci(32) ============================================== Port Src VPI Src VCI Operation Status ============================================== Total number of SPVCs = 0 switch_prompt # : 5a2 : 100 SmartSwitch ATM Switch Reference Manual 2-289 Spvc...
SpvcAddress Use SPVCAddress to configure a target address on the switch. The target address allows the switch to act as the target switch in an SPVC or SPVP connection. The SPVC or SPVP is established (added) at the source switch.
SpvcBase SpvcBase Use SpvcBase to display status information about SPVCs and SPVPs on the switch. Operators show Parameters This attribute has no input parameters. Just type Output Parameter [Currently Failing SPVC] [Currently Failing SPVP] [SPVC Call Failures] [Notify Interval] [Failure Trap Enable]...
SpvcFailed Use SPVCFailed to display failed SPVCs on the switch. An SPVC fails when its call setup request is rejected by the target switch. The SPVC call request is sent from this switch (the source switch) to the target switch.
Page 324
Executing this command : show SpvcFailed PortNumber(ALL) SourceVpi(0) SourceVci(32) ========================================================== Port Src VPI Src VCI Curr.Fail-Time-Stamp ========================================================== Total number of Failing SPVCs = 1 2-296 SmartSwitch ATM Switch Reference Manual Description Displays information on failed SPVCs. (Hr:Min:Sec) 0: 0: 0...
SpvcRestart Use SpvcRestart to restart a failed SPVC on the switch. An SPVC fails when its call setup request is rejected by the target switch. The SPVC call request is sent from this switch (the source switch) to the target switch. SpvcRestart uses SPVC target information provided by the last attempt to establish the SPVC (information provided as input parameters by the Spvc attribute).
SpvcTarget Use SpvcTarget to display SPVC target information on the switch. Information is displayed only if the switch is the destination (target) of an SPVC. The SPVC is established (added) at a source switch across the ATM network. Operators show...
Spvp (SmartSwitch 6500 Only) Use SPVP to add, delete, or show soft PVPs (SPVPs) on the switch. An SPVP connects this switch (the source switch) to a switch across the ATM network (the target switch). Note Before adding an SPVP at this switch, you must configure the target address at the target switch.
Page 330
2-302 SmartSwitch ATM Switch Reference Manual appears next to parameters that are available only through the </d> Description Physical port number on the switch. (Same as the [PortNumber] input parameter.) VPI allocated to the SPVP source port. (Same as the [SourceVpi] input parameter.) Indicates operational status of the SPVP.
Description Type of traffic in the backward (target to source) direction. Index of the forward (source to target) traffic descriptor. Index of the backward (target to source) traffic descriptor. SmartSwitch ATM Switch Reference Manual 2-303 Spvp Description Adds an SPVP.
Page 332
Unsupported combination of traffic parameters. AAL parameters cannot be supported. Invalid call reference value. Identified channel does not exist. Incompatible destination. Invalid endpoint reference. Invalid transit network selection. Too many pending add party requests. 2-304 SmartSwitch ATM Switch Reference Manual...
Page 333
Port Src VPI Operation Status =================================== Total number of SPVPs = 0 switch_prompt# add spvp PortNumber() SourceVpi(0) DestinationSelectType(REQUIRED) DestinationVPI(0) TargetAddress() 11:11:11:11:11:11:11:11 ForwardTrafficDescriptorIndex() BackwardTrafficDescriptorIndex() RetryInterval(10000) RetryLimit(0) RetryThreshold(1) Added SPVP successfully. : 5a2 : 11:11:11:11:11:11:11:11:11:11:11:11: SmartSwitch ATM Switch Reference Manual 2-305 Spvp...
Page 334
PortNumber(ALL) SourceVpi(0) SourceVci(32) ====================================== Port Src VPI Operation Status ====================================== Total number of SPVPs = 0 switch_prompt # 2-306 SmartSwitch ATM Switch Reference Manual : 5a2 : 5a2 : 11:11:11:11:11:11:11:11:11:11:11:11:11:11:11 : Connected : 10000 : CBR : CBR : 5a2...
(SmartSwitch 6500 Only) Use SpvpFailed to display failed SPVPs on the switch. An SPVP fails when its call setup request is rejected by the target switch. The SPVP call request is sent from this switch (the source switch) to the target switch.
Page 336
SpvpFailed Examples show spvpfailed switch_prompt # Executing this command : show SpvpFailed PortNumber(ALL) SourceVpi(0) ========================================================== Port Src VPI Curr.Fail-Time-Stamp (Hr:Min:Sec) ========================================================== 0: 0: 0 Total number of Failing SPVPs = 1 2-308 SmartSwitch ATM Switch Reference Manual...
(SmartSwitch 6500 Only) Use SpvpRestart to restart a failed SPVP on the switch. An SPVP fails when its call setup request is rejected by the target switch. The SPVP call request is sent from this switch (the source switch) to the target switch. SpvpRestart uses SPVP target information provided by the last attempt to establish the SPVP (information provided as input parameters by the Spvp attribute).
(SmartSwitch 6500 Only) Use SpvpTarget to display SPVP target information on the switch. Information is displayed only if the switch is the destination (target) of an SPVP. The SPVP is established (added) at a source switch across the ATM network.
SSCOPConfig Use SSCOPConfig to set or display switch Service-Specific Connection-Oriented Protocol parameters. SSCOP parameters control how the switch interoperates with other switches. Note The following applies to SmartSwitch 6500 only: You can hot-swap TSMs. Hot-swapping is replacing a module when the chassis is powered up. If you replace a TSM with another TSM of the same type (same I/O ports), existing configuration of port parameters is not affected.
Page 342
Rate at which BEGIN and END PDUs are generated during link establishment of release. (Same as the [CCTime] input parameter.) [RxWindowSz] Receive window size when SSCOP stack is initialized. 2-314 SmartSwitch ATM Switch Reference Manual Value/Field Size 1000-2000 10000-15000 1000-2000...
Operators show Parameters Input Parameter Description [PortNumber] Port number on the switch. 1A1 to 8B4 (for physical ports), Output Parameter [Port#] [Num BEGIN Transmitted] [Num BEGIN Received] [Num BEGIN Retransmit Transmitted] [Num BEGIN Retransmit Received] [Num BEGIN ACK Transmitted]...
Page 345
Number of END retransmit PDUs transmitted. Number of END retransmit PDUs received. Number of END ACK PDUs transmitted. Number of END ACK PDUs received. Number of POLL PDUs transmitted. Number of POLL PDUs received. SmartSwitch ATM Switch Reference Manual 2-317 SSCOPStatistics...
Page 346
[Num Error PDUs Received] Description Operator Parameters / Permissions show sscopstatistics [PortNumber] <portnumber> 2-318 SmartSwitch ATM Switch Reference Manual Description Number of STAT PDUs transmitted. Number of STAT PDUs received. Number of USTAT PDUs transmitted. Number of USTAT PDUs received.
Page 347
No of times NORESPONSE expired No of max times TCC timer expired No of Invalid PDUs received No of Error PDUs received switch_prompt # : 1a2 : 1A2 : 17 : 17 : 17 : 17 SmartSwitch ATM Switch Reference Manual 2-319 SSCOPStatistics...
High VCI (virtual circuit identifier) number. [High Type] High port connection type (PMP or PTP). [Creation Time] Time when the SVC was established (with respect to the boot time on the switch). Displayed in Hour:Minute:Seconds format. 2-320 SmartSwitch ATM Switch Reference Manual Value/Field Size A1 to B4 (physical-2500 family), A1.n to B4.n (virtual-2500 family),...
Page 349
# Description Displays SVC(s) for s apecified port High CreationTime Vci Type | (Hr:Min:Sec) 0: 5:20 0: 5:20 0: 5:20 0: 5:20 0: 5:20 0: 5:20 0: 5:20 0: 5:20 0: 5:20 0: 5:20 SmartSwitch ATM Switch Reference Manual 2-321...
[High Port] [High VPI] [High VCI] [High Cast Type] [Creation Time] [Admin Status] </d> 2-322 SmartSwitch ATM Switch Reference Manual Value/Field Size show SVC Description Identifier for each unique connection. (Same as the [CrossConn] input parameter.) Port receiving the backward flow of the high/low pair.
Page 351
Number of cells dropped in the backward direction. Number of early packet discard packets dropped in the forward direction. Number of early packet discard packets dropped in the backward direction. Description Displays SVC(s) by connection ID. SmartSwitch ATM Switch Reference Manual 2-323 SVCById...
Page 352
Number of Cells Received in the Bkw Direction Number of Cells Dropped in the Bkw Direction Number of Epd Packets Dropped in the Bkw Direction : 0 switch_prompt # 2-324 SmartSwitch ATM Switch Reference Manual High CreationTime Vpi Vci Type |...
Switch Use Switch to backup or restore the switch configuration file. Operators backup, restore Parameters This attribute has no output parameters. Input Parameter Description [ServerIP] IP address of the backup server. [Path] Pathname of the backup directory. 256 characters Value/Field Size...
Page 354
Copies the current configuration of the master TSM/CPU module to a backup file at an end station. This command backs up the switch configuration only. It does not back up the load image. It prompts you for the IP address of the workstation to which you are saving the switch configuration as well as the backup path and filename.
7-15 characters Description Name of the switch. (Same as the [SwitchName] input parameter. IP address of the Ethernet port on the switch. (Same as the [IPAddress] input parameter.) IP netmask of the Ethernet port. (Same as the [IPNetMask] input parameter.) Base MAC (media access control) address for the TSM/CPU module.
Page 356
Total heap space used, total memory allocated to heap, and percent of free memory (bytes/bytes/%). Description Runs automatically when you first configure the switch, then prompts you for the required input. Enter if you want to change any of the above switchconfig parameters after the initial switch configuration.
Page 357
# Description Displays hardware and software configuration information about the switch. It also includes auto-detect hardware configuration information, such as number of switch boards and memory, and software information such as the type and version. Any future hardware or software changes will be detected automatically when the switch is rebooted.
# 2-330 SmartSwitch ATM Switch Reference Manual Value/Field Size Up to 19 characters Description Changes the name you gave your switch. You can also change switchname using modify switchconfig change other switch features at the same time. Default switch_1...
SwitchTrafficCongestion Use SwitchTrafficCongestion to manage global switch traffic congestion thresholds on the switch. Operators modify, show Parameters Parameter [LowEPDWatermark [HighEPDWatermark] [CLP1_DiscardWatermark] [RMCellMarkingEnable] [ExplicitRateMarkingEnable] [EFCIMarkingEnable] Description Threshold (in cells) used by the switch to trigger low EPD (early packet discard), EFCI, and backward RM (resource management) cell marking.
Page 360
CLP1 Discard Threshold RM Cell Marking Enable EFCI Cell Marking Enable Explicit Rate Marking Enable switch_prompt # 2-332 SmartSwitch ATM Switch Reference Manual Descriptions Modifies the congestion control parameters for the switch. Displays the current traffic congestion settings for the switch.
MaxBurstSize CLP0 (6) PeakCellRate CLP0+1, SustCellRate CLP0, MaxBurstSize CLP0, Tag CLP = 1(7) BestEffort (11) Positive integer show trafficde- Zero or positive integer Zero or positive integer Zero or positive integer SmartSwitch ATM Switch Reference Manual 2-333 TrafficDescriptor Default No default...
Page 362
(Unspecified), 1 (Class 1), 2 (Class 2), 3 (Class 3), or 4 (Class 4). [Peak Cell Rate Peak cell rate CLP=0 (in kilobits per second). CLP_0] 2-334 SmartSwitch ATM Switch Reference Manual Value/Field Size Zero or positive integer Zero or positive integer...
TrapCommunity Use TrapCommunity to manage the list of hosts that the switch sends trap notifications to concerning significant events. Each trap community has a name, IP address, and port number. The trap community name and address combination must be unique.
Page 366
# switch_prompt # show trapcommunity TrapCommunity Name =========================================================================== trapcomm switch_prompt # 2-338 SmartSwitch ATM Switch Reference Manual Descriptions Displays all trap communities configured on the switch. : boris : 204.95.77.148 : 100 IP Address Port 204.95.77.147 204.95.77.148 : boris : 204.95.77.148...
TrustedNMS Use TrustedNMS to configure a trusted network management system (NMS) on the switch. The trusted NMS is identified by its IP address. The trusted network management system is the only NMS allowed to perform critical operations such as: •...
Accessing the Boot Load Commands Boot load commands are executed from the boot load prompt. The boot load prompt is not part of the switch console, and is accessible only after a reboot and before the switch software is loaded. Perform the following steps to gain access...
Example =>clfs Clearing Flash File System, please wait... Successfully cleared Flash File System => After you return to the switch console (exit the boot prompt) following Note series of messages appears at the console ending with the At the password:...
POST OFF => df Command (download firmware) to download software images from a TFTP/Bootp server to the flash RAM of the switch. Note Be sure the location and names of the image files are known to the TFTP/Bootp server to allow the server to automatically download the files to the switch.
New Switch Software programmed successfully => go Command Use the command to exit the boot load prompt and run switch software (with or without POST). Parameter Explanation Bypass POST and go directly to switch software. Run POST, and then run switch software.
1 ..changes the Boot Load default to be Boot Load Software1 Changes Boot Load default to be Boot Load Software (0) or (1) (1) UP (2) UP (9) DOWN SmartSwitch ATM Switch Reference Manual 3-5 he Command ) can be...
Command ponf Command to set whether POST diagnostics are run by default when the switch is started. ponf Parameter Explanation POST is off. Switch goes directly to start-up. POST is on. Switch runs POST before going to switch operating software.
Boot Load Commands swms Command swms Command to tell the switch to transfer TSM/CPU mastership to the redundant CPU/TSM. swms Examples =>swms Transferring mastership to slave TSM/CPU... => SmartSwitch ATM Switch Reference Manual 3-7...
Application Programming Interface Address Resolution Protocol ASCII American Standard Code for Information Interchange Asynchronous Transfer Mode Available Cell Rate Bridged Ethernet Bit Error Ratio (Rate) B-ICI Broadband Inter-Carrier Interface B-ISDN Broadband Integrated Services Digital Network SmartSwitch ATM Switch Reference Manual A-1...
Page 378
Congestion Indicator Cell Loss Priority Cell Loss Ratio CMIP Common Management Information Protocol Communication Class of Service Customer Premise Equipment Central Processing Unit Cyclic Redundancy Check Cell Relay Service Convergence Sublayer Cell Transfer Delay A-2 SmartSwitch ATM Switch Reference Manual Acronyms...
Page 379
EISA Extended Industry Standard Architecture ELAN Emulated Local Area Network Electro-Magnetic Interference Enterprise Network Roundtable End of Frame Early Packet Discard EPROM Erasable Programmable Read-Only Memory Electro-Static Device End System Identifier Expansion Switch Module SmartSwitch ATM Switch Reference Manual A-3...
Page 380
Generic Cell Rate Algorithm Generic Flow Control Header Error Check IEEE Institute of Electrical and Electronic Engineers ICMP Internet Control Message Protocol Identification Number Information Element IETF Internet Engineering Task Force IISP Interim Inter-Switch Signaling Protocol A-4 SmartSwitch ATM Switch Reference Manual Acronyms...
Page 381
ISDN Integrated Service Digital Network JPEG Joint Photographic Experts Group KB/S Kilobits per second Local Area Network LANE LAN Emulation LAN Emulation LE-ARP LAN Emulation-Address Resolution Protocol LANE Client LECS LAN Emulation Configuration Server SmartSwitch ATM Switch Reference Manual A-5...
Page 382
Metropolitan Area Network MB/S Megabits per second Maximum Burst Size Minimum Cell Rate Management Information Base Multi-Mode Fiber Multi-Point Main Switch Module Maximum Transfer Unit NAKS Negative Acknowledges NDIS Network Driver Interface Specification A-6 SmartSwitch ATM Switch Reference Manual Acronyms...
Page 383
Operations, Administration, Maintenance and Provisioning OC-1 Optical Carrier 1 OC-N Optical Carrier n (where "n" is an integer) Open Data-link Interface Out of Band Open Systems Interconnection Personal Computer Priority Control Peripheral Component Interconnect Peak Cell Rate SmartSwitch ATM Switch Reference Manual A-7...
Page 384
Quality of Service QSAAL Q-Signaling ATM Adaptation Layer. (Q represents the Q-series of the ITU-T (International Telecommunications Union). Read-Only Access Random Access Memory Routing Control Channel Raw Cell Received Receive Deactivated Request for Comment A-8 SmartSwitch ATM Switch Reference Manual Acronyms...
Page 385
Synchronous Transport Module n - concatenated (where ‘n' is an integer) Shielded Twisted Pair STS-1 Synchronous Transport Signal 1 STS-N Synchronous Transport Signal n (where ‘n' is an integer) STS-NC Synchronous Transport Signal n - concatenated (where ‘n' is an integer) SmartSwitch ATM Switch Reference Manual A-9...
Page 386
Trivial File Transfer Protocol Type, Length and Value Unspecified Bit Rate UNI Management Entity User-Network Interface Unnumbered Poll Usage Parameter Control UTOPIA Universal Test and Operations Physical Interface for ATM Unshielded Twisted Pair A-10 SmartSwitch ATM Switch Reference Manual Acronyms...
Page 387
Variable Bit Rate/Non-real Time Virtual Circuit Virtual Channel Connection Virtual Channel Identifier Virtual Channel Link VLAN Virtual LAN Virtual Path Virtual Path Connection Virtual Path Identifier Virtual Private Network Virtual Tributary Wide Area Network SmartSwitch ATM Switch Reference Manual A-11...
APPENDIX B EVENT/ALARM MESSAGES The SmartSwitch 2500 family and SmartSwitch 6500 record and report their operation in real-time using events and alarms. An event is the occurrence of a significant activity. Examples of events are a port going down or a client joining an ELAN.
The event ID is an 8 or 9-digit decimal number that allows you to identify the source of the event or alarm. The first five or six digits indicate the software module associated with the switch activity. The remaining digits identify the specific type of activity.
A complete list of event and alarm messages is beyond the scope of this manual. If a recovery action is not apparent from the message text (or context in which the switch activity occurred), contact your Cabletron representative for assistance. 000:00:23:502...
APPENDIX C TECHNICAL SUPPORT This appendix tells you what to do if you need technical support for your switch. Cabletron offers several support and service programs that provide high-quality support to our customers. For technical support, first contact your place of purchase. If you need additional assistance, contact Cabletron Systems, Inc. There are several easy ways to reach Cabletron Customer Support and Service.
Once they confirm the board is defective, they will assign an RMA number. Payment, shipping instructions, and turnaround time will be confirmed when the RMA number is assigned. C-2 SmartSwitch ATM Switch Reference Manual...