Spvc
Input Parameter
[BackwardTrafficDescriptor
Index]
[RetryInterval]
[RetryLimit]
[RetryThreshold]
In the Output Parameter table below,
(detailed) command
/d
Output Parameter
[Port]
[Src VPI]
[Src VCI]
[Operation Status]
[Total Number of SPVCs]
[Target Address]
[Target VPI]
[Target VCI]
[Last Release Cause]
[Retry Interval]
[Retry Timer]
2-284 SmartSwitch ATM Switch Reference Manual
Description
Index of the backward (target to source) traffic
descriptor.
Time interval between SPVC retries.
Maximum number of SPVC retries.
Number of consecutive failed setup attempts for
a particular SPVC before the
SPVCCCallFailures object is incremented.
appears next to parameters that are available only through the
</d>
(
)
Description
Physical port number on the switch. (Same as the [PortNumber] input
parameter.)
VPI allocated to the SPVC source port. (Same as the [SourceVpi] input
parameter.)
VCI allocated to the SPVC source port. (Same as the [SourceVci] input
parameter.)
Indicates operational status of the SPVC. Possible values are: Connected,
Establishment in Progress, Retries Exhausted, and Other.
Indicates the total number of SPVCs on the switch.
Destination (target) address to which the SPVC attempts to connect.
VPI allocated to the target port. (Same as the [DestinationVpi] input
parameter.)
VCI allocated to the target port. (Same as the [DestinatiionVci] input
parameter.)
Code that describes cause of SPVC failure (why SPVC has failed to
connect) (see Table 2-10).
Time interval between SPVC retries.
Value of the retry timer.
Value/Field Size
0-3600000 milliseconds
0-65535
0-65525
show spvc
Default