Procedure For Allocating I/O In The Master - Omron DRT2 Series Operation Manual

Devicenet slaves
Hide thumbs Also See for DRT2 Series:
Table of Contents

Advertisement

Overview of Analog Slaves
7-1-8

Procedure for Allocating I/O in the Master

Application
Allocating
Using default allo-
analog
cation
input only in
Scaling with
the Master
desired industry
unit
Averaging exter-
nal analog inputs
Allocating
Allocating the
other values
maximum (peak)
(not analog
or minimum (bot-
input) in the
tom) value in the
Master
Master
Allocating the top
or valley value in
the Master
Allocating top or
valley timing in the
Master
Allocating the rate
of change in the
Master
Allocating the alarm output for
analog input, peak/bottom,
top/valley, or rate of change
value in the Master
Monitoring the cumulated value
from the Configurator.
128
Step 1
Enable/disable
functions
Set using the Configurator in the
Slave's Edit Device Parameters Window
Not required.
Not required.
Set the scaling func-
Not required.
tion.
Set the moving average
Not required.
processing operation.
Set the peak/bottom
Allocate the
hold function.
maximum (peak)
or minimum (bot-
tom) value as
Analog Data 1 or
Analog Data 2.
Set the top/valley hold
Allocate the top
function.
or valley value as
Analog Data 1 or
Analog Data 2.
Set the top/valley hold
Not required.
function.
Set the rate of change
Allocate the rate
operation function.
of change value
in Analog Data 1
or 2.
Set the HH, H, L, and
Allocate any of
LL alarms for the com-
the analog data
parator function.
types in Analog
Data 1.
Set the cumulative
Not required.
count function.
Step 2
Select analog
1. Allocate I/O
data
data in fixed
combinations
Set using the
Configurator
under Default
Connection Path
in the Slave's Edit
Device
Parameters
Window
Not required.
Not required.
Not required.
Select an I/O data
(pattern) that
includes either
Analog Data 1 or
Analog Data 2,
and select the
Hold Flag.
Select an I/O data
(pattern) that
includes Analog
Data 1 or Analog
Data 2, and select
the Hold Flag.
Select an I/O data
(pattern) that
includes the
Top/Valley Detec-
tion Timing Flag,
and select the
Hold Flag.
Select an I/O data
(pattern) that
includes Analog
Data 1 or 2.
Select an I/O data
(pattern) that
includes the Ana-
log Status Flags.
Not required.
Section 7-1
Step 3
2. Allocate
user-defined data
in user-defined
area
Set using the
Configurator
under the
Connection Tab
in the Master's
Edit Device
Parameter
Window
---
---
---
Specify either Ana-
log Data 1 or Ana-
log Data 2, and the
Hold Flag.
Specify either Ana-
log Data 1 or Ana-
log Data 2, and the
Hold Flag.
Specify the
Top/Valley Detec-
tion Timing Flag
and the Hold Flag.
Specify either Ana-
log Data 1 or 2.
Specify the Ana-
log Status Flags.
Not required.