Omron XWT-0D16-1 Operation Manual (282 pages)
DeviceNet Slaves
Brand:
Omron
| Category:
Industrial Electrical
| Size: 6 MB
Table of Contents
Precautions
10
Table of Contents
10
Intended Audience
11
General Precautions
12
Safety Precautions
13
Operating Environment Precautions
14
Application Precautions
15
EC Directives
17
Section 1 Smart Slaves and Features
18
DRT2 Features
19
Overview
19
Features
19
DRT2 Slaves
23
General-Purpose Slaves
23
Environment-Resistive Slaves
23
Analog Slaves
23
Smart Slave Feature Support
24
Installing and Connecting Slaves
25
Section 2 Example System Startup
28
Basic Procedures and Configuration Examples
29
Basic Procedures
29
System Configuration Example
29
Preparations
30
Selecting Units
30
Wiring
30
Communications Power Supply
30
Setting and Wiring Hardware
31
Mounting and Setting the Master Unit
31
Mounting and Setting Slaves
32
Mounting Connecting Devices
33
Connecting Cables
33
Starting Communications
34
Creating I/O Tables for the Master Unit
34
Starting the System
34
Creating and Registering Scan Lists
35
Checking Operation
36
Indicator Status
36
Reading and Writing Data
36
Section 3 Common Slave Specifications
38
Common Slave Specifications
39
Communications Specifications
39
MS and NS Indicators
39
Devicenet Remote I/O Communications
41
Overview of Remote I/O Allocations for Smart Slaves
41
I/O Allocations for Smart Slaves
43
I/O Allocation with the Configurator (Ver. 2.@ or Later)
47
Section 4 Functions
54
Maintenance Mode Window and Main Window
55
Maintenance Mode Window
55
Common Slave Functions
56
Automatic Baud Rate Recognition
56
Network Power Supply Voltage Monitor
57
Unit Conduction Time Monitor
58
Slave Comments
59
I/O Comments
61
Communications Error History Monitor
63
Last Maintenance Date
64
Remote I/O Terminal and Environment-Resistive Terminal Functions
65
I/O Power Status Monitor
65
Input Filter
66
Power on Delay
68
Contact Operation Counter
68
Total on Time Monitor
70
Operation Time Monitor (Remote I/O Terminals Only)
72
Sensor Disconnected Detection (Environment-Resistive Terminal Input Units Only)
75
Detection of Sensor Power Short-Circuit (Environment-Resistive Terminal Input Units Only)
76
External Load Short-Circuit Detection (Environment-Resistive Terminal Output Units Only)
78
Section 5 General-Purpose Slaves
82
Common Specifications for General-Purpose Slaves
83
Current Consumption and Weights
83
Connecting Communications Cables to General-Purpose Slaves
84
Connecting Communications Cables
84
Connecting Communications Cables to the Nodes
86
Mounting Terminating Resistors
87
Remote I/O Terminals with Transistors
88
Node Address, Baud Rate, and Output Hold/Clear Settings
88
Increasing I/O Using an Expansion Unit
90
Remote I/O Terminals with Transistors and 16 Inputs: DRT2-ID16 (NPN) and DRT2-ID16-1 (PNP)
92
Remote I/O Terminals with Transistors and 16 Outputs: DRT2-OD16 (NPN) and DRT2-OD16-1 (PNP)
94
XWT-ID08 (NPN) and XWT-ID08-1 (PNP)
97
XWT-ID16 (NPN) and XWT-ID16-1 (PNP)
100
Remote I/O Terminal Expansion Units with Transistors and 8 Outputs:
103
Remote I/O Terminal Expansion Units with Transistors and 16 Outputs:
105
Mounting in Control Panels
108
5-3-10 Wiring the I/O Power Supply and I/O Lines
108
Section 6 Environment-Resistive Slaves
110
Common Specifications for Environment-Resistive Slaves
111
Current Consumption, Weight, Enclosure Ratings
111
I/O Indicators
111
Connecting Communications Cables to Environment-Resistive Slaves
112
System with Slaves Using Round Connectors Only
112
System with Slaves Using Round Connectors and Regular Square Connectors
113
Communications Cables for Environment-Resistive Terminals
113
Example System Assembly
115
Environment-Resistive Terminals
116
Node Address, Baud Rate, and Output Hold/Clear Settings
116
Environment-Resistive Terminals with 8 Transistor Inputs (IP67): DRT2-ID08C (NPN) and DRT2-ID08C-1 (PNP)
116
Environment-Resistive Terminals with 16 Transistor Inputs (IP67): DRT2-HD16C (NPN) and DRT2-HD16C-1 (PNP)
121
Environment-Resistive Terminals with 8 Transistor Outputs (IP67): DRT2-OD08C (NPN) and DRT2-OD08C-1 (PNP)
126
Mounting in Control Panels
131
Wiring the Internal Power Supply, I/O Power Supply, and I/O Lines
132
Section 7 Analog Slaves
136
Overview of Analog Slaves
137
DRT2 Analog Slaves
137
Comparison of DRT1 and DRT2 Functions
137
List of Data Processing Functions
139
Analog Data Operation Flowcharts (Analog Input Terminals)
140
Selecting Analog Data (Analog Input Terminals)
140
I/O Data Allocated in the Master
141
Allocating I/O Data in the Master
143
Procedure for Allocating I/O in the Master
145
Application Procedure Flowchart
146
Common Procedures
147
Connecting Communications Cables
147
Node Address and Baud Rate Settings
147
Mounting in Control Panels
148
Wiring the I/O Lines
149
Analog Input Terminals
149
DRT2-AD04 Analog Input Terminals
149
I/O Data Allocation Methods
155
Functions and Settings
165
Calculating the Conversion Cycle
187
Analog Output Terminals
188
DRT2-DA02 Analog Output Terminal
188
I/O Data Types and Allocation Methods
193
Functions and Setting Methods
198
Section 8 Communications Timing
208
Remote I/O Communications Characteristics
209
I/O Response Time
209
Communications Cycle Time and Refresh Time
214
More than One Master in Network
216
System Startup Time
217
Message Communications Characteristics
218
Message Communications Time
218
Section 9 Troubleshooting and Maintenance
220
Indicators and Error Processing
221
Error Occurring in the Slave Unit
221
Troubleshooting
222
Slave Unit Troubleshooting
222
Maintenance
224
Cleaning
224
Inspection
225
Replacing Units
225
Advertisement
Advertisement
Related Products
Omron XWT-0D16
Omron XW6T Series
Omron XW6T-COM1.5X8RD
Omron XW6T-COM1.5X8YL
Omron XW6T-COM1.5X12RD
Omron XW6T-COM1.5X20RD
Omron XW6T-COM1.5X40RD
Omron XW6T-COM1.5X40BL
Omron XW6T-COM2.5X8YL
Omron XW6T-COM2.5X16RD
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL