Common Control Equipment Installation
AGC Peak Detector Decay
Setting a higher decay time will cause the locked AGC gain to be lower when the audio
input level drops towards zero. This will reduce the background noise level when the
channel is idle but slightly reduce the AGC response time.
To set the AGC Peak Detector Decay
1. Press P to set the AGC Peak Detector Decay:
2. Choose the number of seconds for the delay and press the appropriate letter A-H.
Set ANI Options
To select an ANI decoding mode
1. Press A to set the ANI decoding mode.
2. Press N to disable all ANI decoding, D to enable DTMF ANI decoding, F to enable
5/6-Tone ANI decoding, M to enable MDC-1200 ANI decoding, G to enable GE-
Star.
3.
ANI decoding, or S to enable SS1 Selective Signaling decoding.
5/6-Tone ANI Decoding
To set 5/6 Tone options
1. Press F to choose a 5/6-Tone tone set.
2. Choose a tone set from those listed in
3. Press the letter that corresponds to the desired tone set.
MDC-1200 ANI Decoding
To set MDC options
1. Press M to set MDC-1200 options:
2. Press M to enable or disable muting
3. Backspace to the MDC-1200 menu.
4. Press E to choose an Emergency ANI behavior:
58
decay (sec.) = A:0.25, B:0.5, C:1.0, D:2.0, E:3.0, F:4.0,
G:5.0, H:6.0,<BS> :
None,Dtmf,Five,Mdc,Gstar,Ss1,<BS> :
A:eia,B:ccir100,C:zvei1,D:eea,E:zvei2,
F:dzvei,G:pzvei,H:ccir70,<BS>:
Emerg,Muting<BS> :
Enable,Disable<BS> :
Note
The muting option is only functional if the SIMM option is installed.