ZETRON 4000 Series Installation Manual page 218

Table of Contents

Advertisement

Console Programming System
c. If the console displays "THX 084", a checksum error occurred, and the
STOP
5. Move the switch to the run position. The top line of the LCD should show the
name of the configuration file. If the name of the file has fewer than eight
characters, the LCD may display extra characters.
6. If you need to send configuration settings to more than one position, repeat this
procedure as needed.
218
console ignored the rest of the download. This can be caused by a baud rate
change or data corruption.
Warning! If the console displays "DnLoading CPS" or "THX 084", the
console's key-definition database has been corrupted and the
console will not work until a good CPS database is successfully
downloaded. Until the console is fixed, it will always display
"CPSdataErr" when switched back to 'Run' mode and it will
ignore all buttons.
Tip
You can attempt to download again by toggling the console's mode
switch to 'Run' and then back to 'Program'. The display will then
show "PROGRAM" again and a new download from CPSW can start.
025-9533Y