The spare outputs may be programmed as momentary or toggle functions. If spare outputs
7 and 8 are not programmed, they will function as follows for Reverse Selective Calling
mode for both M4x18 button consoles and IntegratorRD workstations:
Spare Output 7
Spare Output 8
For PTT ID mode for IntegratorRD workstations only:
Spare Output 7
Spare Output 8
Additional spare outputs on the M4217:
Spare Output 5
Spare Output 6
The spare outputs are active low (0 V).
Turns on when an ANI is displayed on the console. Can
be used to activate an external alert device.
Produces a 500-millisecond pulse whenever an ANI is
decoded by the console.
Turns on when an emergency ANI is displayed on the
console. Can be used to activate an external alert device.
Produces a 500-millisecond pulse whenever an
emergency ANI is decoded by the console.
Activates with call on Select Channel.
Deactivates when call releases.
Activates with KeyUp.
Deactivates with KeyDown.