ZETRON 4000 Series Installation Manual page 204

Table of Contents

Advertisement

Console Programming System
a. Most paging formats have a setting for Talk Time that should be configured.
b. If you are using the paging format "1000 Call Two Tone" or "100 Call Two
c. If you are using the paging format "Custom (Plectron)" be sure to later
d. The paging format "Alerts" is used to add various alert tones to your pages.
5. If you have additional Leading Digits to assign, repeat this procedure. If you are
finished, click Done.
STOP
204
Talk Time is the predefined amount of time after a page is finished that the
microphone and transmitter are keyed up. After that time expires,
IntegratorRD releases PTT and terminates transmission.
Operators can use the Transmit key or a PTT button to override the default
Talk Time by extending or cancelling the transmission. Once the Transmit key
or a PTT button is pressed, the default Talk Time is cancelled and the
transmitter is keyed up until the key or button is released.
Tone", the details for the code plans are listed in
Material
on page 363.
configure custom calls (see
The following list shows the page character used by the operator to generate
each Alert function:
(0) Beep alert
(D) Delay function
(1) Slow siren alert
(2) Fast siren alert
(3) Hi/Lo warble alert
(4) Fast warble alert
For example, assuming the "Alerts" paging format has been assigned to
leading digit "A", keying A4 on the Model 4018 or 4118 paging/DTMF
keypad enters the Fast Warble alert on the paging stack.
Beep Alert (0) and Delay (D) function are configurable:
• Tone Frequency configures the tone for the Beep Alert.
• ON Duration sets the length of each beep tone.
• OFF Duration sets the delay between each beep tone.
• Count / Delay Time sets the number of beeps for the Beep Alert or the
delay in seconds for the Delay function.
The tones for Alert (1) through (4) are predefined in the console; only their
duration is configurable (by setting Alert Duration).
Warning! When you have configured a Leading Digit and you select
another Leading Digit, the configuration changes you made
are automatically applied. Clicking Cancel only cancels
configuration changes for the currently selected Leading Digit.
Likewise, clicking Revert only reverts configuration changes
for the currently selected Leading Digit.
Appendix C: CPSW Reference
To configure Custom Calls
on page 205).