ZETRON 4000 Series Installation Manual page 108

Table of Contents

Advertisement

Common Control Equipment Installation
Port Configuration Menu
To access the Port features, type P and press Enter. The following menu is displayed:
D) Display current port configuration
L) Logger port select
B) Backplane monitor port select
R) Radio system management port select
Enter desired port option:
To list the ports and what types of data are sent to them, type D and press Enter. The
following menu is displayed.
Report function
-----------------
Logger
Backplane monitor
Radio Management
( 2 Oct 1998 08:24:11.74) Zetron M4048 Service Port (STC1 rev 01.05E)
Enter command (? = help):
To change a port setting, type P <port> and press Enter, where <port> is L, B, or R. (Select
the port that you want to change). The following menu shows the ports to which you can
direct the Logger output after typing "P L" and ENTER.
N) None (disabled)
L) LOGGER port
M) MODEM/SERVICE port
R) RADIO MANAGEMENT port
Enter desired physical port
ANI Display Option
When enabled, the ANI display option sends ANI logging information to the Radio
Management Port (J13), a standard RS-232 serial port. The formatting of the ANI
information is described in
To enable or disable the ANI Display Option, press O followed by Enter. Then press E to
enable or D to disable, followed by Enter.
108
Note
On system reset, the port configurations are set as determined by
the switches on the front of the STC card. Settings changed using
the following menus is effective until the system is reset again, but
the STC switches should be modified if permanent changes are
desired. (Backplane information is only active when a Zetron
service employee is assisting with system diagnostics).
Physical port assigned
----------------------
MODEM/SERVICE
MODEM/SERVICE
RADIO MANAGEMENT
ANI Log
on page 355.