Next, add a dispatcher assigned to the associated Map27 port and set the privileges and
associated groups for this user.
To configure the Dispatcher Units
1. Start the M827BASE for Windows application.
2. Navigate to Fleet Configuration Editor, Edit, Dispatcher Units Editor.
3. Select the Dispatcher Unit Name, the Member of Fleet number (Fleets must be
defined with their applicable Sites), and the Unit Number.
4. Enable Unit is valid.
5. Enter the MAP27 Data Port Assignment.
6. Enter the Direct Dial Number.
7. Define the user-defined control capabilities by enabling the appropriate controls
(System Control Allowed, Repeater Control Allowed, User Control Allowed (with
or without Same Fleet Only, and/or Alarm Control Allowed).
8. Assign the Associated Groups.
9. Select the General and Roaming Classes of Service (COS).
10. Save the data record to the database.