Configuring Console Cards
positions 1-8 but the muting of positions 9-16 are selected based on the switch setting
described above.
If 24-channel operation is selected, the range of 24 channels within the 48-channel system
must be selected using the lower six switches (labeled 0-5). These switches are used to
specify a channel number offset for the 24-channel console. This offset is used to compute
the actual physical channel. For example, if position 3 is a Model 4118 button console
configured to control Channels 1-12, but the channels are physically installed as Channels
23-35, the offset would be "22".
The switches allow you to select an offset in even number increments, such as: +0, +2, +4.
The maximum offset is +46. The switches are set using binary arithmetic where switch 0
is the least significant bit. Possible switch selections are:
The CIC-to-Console data rate is specified by the three switches labeled 19.2K, 9600, and
1200. Only one of these switches should be switched "ON". The default is 9600. The
19.2K switch is not currently used. The 1200 switch should be used with Zetron long haul
modems for remote console installations.