IntegratorRDPS Programming
ANI Receive Timeout
Use the scroll bar to select the number of seconds the console should delay after receiving
the last ANI digit before decoding and displaying the ANI identification. Typically, 1 or 2
seconds is sufficient for automatic ANI calling and 5 seconds for manual ANI calls.
Primary/Secondary ANI Addresses
Each console position can have an address assigned to it. These addresses are used to
select only ANI calls with that address encoded in the ANI. Normally, the primary address
is used to select an individual console, while the secondary address is used to provide a
group call to all consoles. For a group call, the secondary address should be set the same
for all of the positions in the system.
Specified Channels Enabled
When Specified Channels is selected for the ANI Option, a list of channels appears. Use
the check boxes to specify which channels should respond to incoming ANI digits. Mark a
box to enable a channel or clear the box to disable a channel. See
Miscellaneous Parameters
Figure 81: Configuration 1 Miscellaneous Parameters
304
Tip
Navigate to this area from the main window in RDPS by clicking
Misc Params, Miscellaneous Parameters.
Figure
80.
025-9533Y