10. Identify the inlet side of the new filter. This is the side showing the part
11. Attach the inlet side of the new filter to the disconnected tube.
Important:
To attach the filter, hold the fitting at the end of the feed tube in place and
turn the filter. Otherwise, the tube will be twisted and material might leak.
12. Disconnect the old filter from the outlet (bottom) tube.
13. Discard the old filter.
Caution:
The filter contains uncured printing material. Discard the filter in accordance
with applicable environmental regulations.
14. Attach the disconnected tube to the new filter.
Important:
Before connecting the tube to the filter, turn the filter about 90°. When
connecting them, hold the fitting at the end of the tube in place and turn the
filter back to its original position. Otherwise, the tube will be twisted after you
connect it, and material might leak.
15. Wipe the filters, tubes and surrounding area to remove material leaks and
16. Replace the back of the materials cabinet.
DOC-18001 Rev. H
number. A 6mm tube is connected to the inlet. (An 8mm tube is connected
to the outlet.)
Figure 4-153 Filter showing inlet and outlet sides
spills.
4 Operating and Maintaining the Printer
4-103