Stratasys J850/J835 User Guide
If the UV level measured is not acceptable, the wizard calibrates the UV lamp
by adjusting the current supplied to it, and then tests it again.
When all UV tests have finished, the results are displayed, showing the
condition of the lamps after calibration (see Figure 4-130 below).
Figure 4-130 Results and condition of UV lamps after calibration
After examining the UV calibration results:
1. Click Next.
2. Remove the UV sensor and close the printer cover. After confirming the
DOC-18001 Rev. H
items listed in the wizard screen, click Next.
Figure 4-131 UV sensor removal
If the results are not acceptable for quality printing, this is indicated in the
final wizard screen.
4 Operating and Maintaining the Printer
4-89