Stratasys J850/J835 User Guide
2. Close the printer application.
3. Shut down the printer computer, wait 60 seconds after the monitor goes
Caution:
The monitor goes blank as soon as the remote desktop link terminates—
before computer shutdown. Turning off the printer before computer
shutdown can cause damage.
4. Using an 8-mm hex (Allen) key, open the latches that secure the back of the
5. Locate the 10-micron filters, installed for the relevant material.
6. Put on protective gloves.
Warning: Toxic and Corrosive Materials
Prolonged contact with resins could cause skin irritation. Put on protective
gloves before continuing.
7. Disconnect the tube connected to the top (inlet) side of the material filter.
8. Make sure that the fitting at the end of the feed-tube remains attached to
9. Cover the filter with a cleaning cloth (or paper towels) to absorb material
DOC-18001 Rev. H
blank, and turn off the main power switch.
materials cabinet and remove the back of the cabinet.
Figure 4-152 Material filters installed
the tube. Re-attach it, if necessary.
spillage.