10. Holding a new pump cassette with one hand, gently pull on each of the
11. Attach the new pump cassette to the printer.
12. Connect the tubes to the new pump cassette.
13. If necessary, replace the pump cassette on the other waste pump.
14. Connect the ground wire to the printer panel.
15. Attach the panel to the printer.
16. Open the Maintenance Counters screen, scroll down to the General Pumps
DOC-18001 Rev. H
tubes.
Pulling on the tubes before installing the cassette ensures that the pump
mechanism turns freely.
Figure 4-150 Preparing the pump cassette for installation
Fit the cassette into the slots in the housing, and turn clockwise to working
position.
section, and click Reset for the relevant counter(s) (see Figure 4-143 on
page 4-96).