Stratasys J850/J835 User Guide
External UV Meter
The following steps apply when using a stand-alone UV meter. This section
does not apply when using the Stratasys UV sensor box connected to the
printer.
1. When the following screen appears, open the printer and place the UV
2. Lead the cable out of the printer so that you can close the printer, and tape
3. Close the printer, while checking that the sensor does not move out of
4. Set the UV meter to measure mJ/cm2.
5. Set the range on the meter to 2,000.
6. Connect the cable from the sensor to the UV meter.
7. Turn on the UV meter, and wait until "0 0 0.0" appears on the display.
8. In the wizard screen, confirm that the sensor is positioned correctly, and
Continue with "UV Measurement " on the next page.
DOC-18001 Rev. H
sensor (probe) at the rear edge of the tray, in the center.
Figure 4-126 Sensor placement screen
it down to make sure that it does not interfere with the moving print block.
Figure 4-127 Correct UV-sensor placement
position.
click Next.
4 Operating and Maintaining the Printer
4-87