Stratasys J850/J835 User Guide
UV Measurement
The UV lamps power up and stabilize. (This takes several minutes.) Then, the
print block passes over the sensor and the wizard compares the measured
radiation to the recommended level for each UV lamp and printing mode.
During this process, which takes 20–40 minutes, you need to monitor the
progress as displayed in the wizard screen.
Figure 4-128 UV measurement progress
When using a stand-alone radiation meter (not the Stratasys UV sensor box
connected to the printer): Reset the meter and enter the reading
(measurement) when you are prompted to do so.
Figure 4-129 UV Measurement dialog box