Table 3-11 Main Measurement Functions (continued)
Item
PF
Power factor
CF
Crest factor
F
Synchronization frequency

3.4.10 Switching the Display Format (RMS/AVG/Peak)of the Measured Value

You can switch the display format of the measured value (RMS/AVG/Peak) for the output voltage
and output current. The items which are displayed in each measuring mode are shown in Table 3-12.
Table 3-12 The Measuring Mode for the Measured Values of the Output Voltage and
Measuring
mode
RMS
AVG
Peak
 Operation procedures using soft-keys
1. Press the [Measure] soft-key and select [2:Measure]. The [Measure] window opens.
DP420LS/DP480LS
The power factor of the load. The power
factor of the phase is displayed when in
the phase voltage display in the
polyphase system. It is not displayed
when in the line voltage display.
The crest factor of the output current
(peak value/effective value). It is not
displayed for the line voltage display in
the polyphase system.
The measured frequency value of the
synchronization signal source when the
signal source is SYNC.
Output Current
Items to be Displayed
(Output Voltage, Output Current)
V, I, Ipk-Hold
Vavg, Iavg, Ipk-Hold
Vmax, Vmin, Imax, Imin, Ipk-Hold
3.4 Using the Continuous Function
Description
Unit
Hz
47