RMS current limiter
Setting range
Factory default

11.14 Setting Range Limit Function

This is the limit function for the setting of the internal signal source. It works when the signal source
is INT, VCA (frequency setting limit only), SYNC (voltage setting limit only), or ADD (internal
signal source only). The limitation does not work for the Sequence and Simulation. It does not also
work for the external signal source of EXT and ADD.
In the polyphase system, the setting is common to all the phases.
Voltage setting limit 1 (in the AC mode, and sine wave or clipped sine wave is selected)
Setting range
(effective value)
Factory default
Resolution
*37: The line voltage setting is available only when the output voltage setting is set as the line voltage
and sine wave is selected in the balanced mode of the polyphase system.
Voltage setting limit 2 (other than Voltage setting limit 1, phase voltage setting only) *38
Setting Range
Positive
(Peak value)
voltage
Factory default
Negative
Setting Range
(Peak value)
voltage
Factory default
Resolution
*38: The limitation is applied to the additional values of the AC voltage setting (recalculated to a peak
value) and the DC voltage setting.
Frequency setting limit (the lower limit  the upper limit) *39
Upper limit
Setting Range
Factory default
Setting Range
Lower
limit
Factory default
Resolution
*39: In the AC mode, the setting range is 40.00 Hz to 550.00 Hz.
DP420LS/DP480LS
24.0 A to 504.0 A / 24.0 A to 252.0 A
 21.0 A to 441.0 A / 21.0 A to 220.5 A
504.0 A / 252.0 A  441.0 A / 220.5 A
Single
Phase voltage setting
0.1 V to 155.0 V / 0.1 V to 310.0 V
*37
Phase voltage setting, 155.0 V / 310.0 V
Phase voltage setting: 0.1 V
Single
+0.1 V to +220.0 V / +0.1 V to +440.0 V
+220.0 V / +440.0 V
220.0 V to 0.1 V / 440.0 V to 0.1 V
220.0 V / 440.0 V
0.1 V
Single
1.00 Hz (AC mode : 40.00 Hz) to 550.00 Hz
550.00 Hz
1.00 Hz (AC mode : 40.00 Hz) to 550.00 Hz
1.00 Hz (AC mode : 40.00 Hz)
0.01 Hz
11.14 Setting Range Limit Function
Polyphase system
Line voltage setting
(single-phase three-wire)
0.2 V to 310.0 V
/ 0.2 V to 620.0 V
Line voltage setting
(three-phase four-wire)
0.2 V to 268.4 V
/ 0.2 V to 536.8 V
line voltage setting: 0.2 V
Polyphase system
Polyphase system
247