4. Advanced Operation
4.27

Restoring to the Factory Default Setting (Reset)

If you reset this product, the setting items marked with  in Table 4-17 are restored to the factory
default settings. Ensure that you reset this product in the output off state.
Setting Item
Output on/off
Output range
AC/DC mode
Signal source
External synchronization signal (LINE
or EXT)
AC voltage setting
Frequency
Output waveform
Output on phase
Output off phase
Phase voltage/Line voltage setting
selection
Line voltage setting
Phase angle setting
Balanced/Unbalanced
DC voltage setting
Current limiter
Setting range limit
External input gain
Phase to be measured
Output function
DC offset
Measurement display mode
Measurement unit selection
Power unit energization setting
Remote sensing
AGC
Autocal
184

Table 4-17 Setting Items to be Reset

Reset
×
×
×
Factory default setting
Off
100 V range
AC mode
INT
LINE
0 V
50 Hz
Sine wave
0.0 deg
Enabled, 0.0 deg
Phase voltage
0 V
Single-phase three-wire: 180 deg
Three-phase: 120, 240 deg
Balanced
0 V
Refer to 11.13
Refer to 11.14
0
L1
Continuous
0 mV
Normal
rms
All enabled (energization)
Off
Off
Off