8.13
8.13.1
8.13.2
S
Maintenance manual
GMK5250L
Air conditioning system
Checking the air conditioning system
•
Check the air-conditioning system in the same way as when checking it on
à
Checking the air conditioning system , p. 7 - 131.
the carrier;
Cleaning the condenser fins
Risk of damage to the condenser.
Do not use a high pressure cleaner or steam jet cleaner. The powerful jet
may damage the fins. Use only compressed air for cleaning.
Depending on the power of the air-conditioning system (3 KW or 6 KW),
different condensers are installed (type A or B).
•
Switch the air conditioning system off.
•
Clean the condenser fins (1) with com-
pressed air.
3 302 744 en
Maintenance work on the superstructure
8.13 Air conditioning system
M 1
M 1
8 - 81
Need help?