Maintenance work on the superstructure
8.6 Hydraulic system
Establishing the
operating
conditions
S
8 - 46
After having changed the oil filters and topping up the oil, you must
re-establish the operating conditions.
Risk of damage to the hydraulic pumps.
Open the valve prior to starting the engine.
This prevents damage to the hydraulic pumps.
Start the engine.
Carry out all hydraulic functions several times to remove any air in the
system.
Check that none of the oil filters is leaking.
Check the oil level through the inspection glass on the hydraulic oil tank.
Top up oil, if necessary;
Opening the valve
Open the valve – lever (1) parallel to the line.
à
p. 8 - 45.