G
O
7.15.4
Spare parts and
tools
Prerequisites
Maintenance manual
GMK5250L
Risk of accidents from hydraulic oil spraying out.
Never tighten any leaking connections when the system is under pressure.
Change pipes and hose lines only when the system is depressurised.
Risk of environmental damage due to leaking consumables.
Immediately repair or have leakages in the hydraulic system repaired to
ensure that no hydraulic oil escapes, seeps into the ground or reaches
waterways when the crane is being used.
After parts have been changed
•
Bleed the carrier's hydraulic system;
p. 7 - 114.
If damage cannot be rectified immediately or further damage is likely
•
Notify
Manitowoc Crane Care
crew.
Cleaning the magnetic rods
Designation
Filter
Packing set
– Receptacle, approx. 5 l (1.5 gal);
– The truck crane must be standing on a level surface.
– The engine must be switched off and secured against unauthorised use;
à
p. 2 - 3.
– During the first 100 operating hours: Clean the magnetic rods weekly.
à
or an authorised GROVE dealer or your repair
à
p. 2 - 4.
3 302 744 en
Maintenance work on the carrier
7.15 Hydraulic system
Bleeding the hydraulic system ,
Quantity
GROVE part no.
2
03329152
2
03135778
M 3
s
7 - 103
Need help?
Do you have a question about the Grove GMK 5250L and is the answer not in the manual?