Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
Check the
following
G
7 - 36
Risk of burns if the exhaust system is hot.
During operation, the exhaust system heats up to 400 °C (750 °F). Wear
suitable gloves and wait until the exhaust system has cooled down. Make
sure not to touch any hot parts.
After checking
•
Start the engine.
•
Check the AdBlue system gauge on the display in the driver's cab;
à
p. 7 - 34.
•
Monitor, if exhaust gases leak from possibly damaged places in the
exhaust system.
•
Switch off the engine.
If you discover any damage
Have any damaged parts of the exhaust system replaced immediately by
Manitowoc Crane Care
•
Check the exhaust pipes (2) from the
engine (1) to the silencer (3) for damage.
The exhaust pipes (2) may not have any
holes or cracks.
•
Check that the area around the exhaust
pipes is free of loose components which
could burn by coming into contact with the
hot exhaust system.
•
Check the filler neck for injecting AdBlue for
external damage.
or an authorised GROVE dealer.
3 302 744 en
Maintenance manual
GMK5250L
Need help?
Do you have a question about the Grove GMK 5250L and is the answer not in the manual?