Manitowoc Grove GMK 5250L Maintenance Manual page 112

Hide thumbs Also See for Grove GMK 5250L:
Table of Contents

Advertisement

Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
Check the
following
G
7 - 36
Risk of burns if the exhaust system is hot.
During operation, the exhaust system heats up to 400 °C (750 °F). Wear
suitable gloves and wait until the exhaust system has cooled down. Make
sure not to touch any hot parts.
After checking
Start the engine.
Check the AdBlue system gauge on the display in the driver's cab;
à
p. 7 - 34.
Monitor, if exhaust gases leak from possibly damaged places in the
exhaust system.
Switch off the engine.
If you discover any damage
Have any damaged parts of the exhaust system replaced immediately by
Manitowoc Crane Care
Check the exhaust pipes (2) from the
engine (1) to the silencer (3) for damage.
The exhaust pipes (2) may not have any
holes or cracks.
Check that the area around the exhaust
pipes is free of loose components which
could burn by coming into contact with the
hot exhaust system.
Check the filler neck for injecting AdBlue for
external damage.
or an authorised GROVE dealer.
3 302 744 en
Maintenance manual
GMK5250L

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Grove GMK 5250L and is the answer not in the manual?

Table of Contents

Save PDF