(1) Display and output condition for system alarms
Alarm description
Normal
10 μP Fault
Microprocessor
(CPU) failure
11
EEPROM
EEPROM failure
Fault
12 Sub uP Fault
Substitute
mcroprocessor
(CPU) failure
13 EX Pwr Fault
Extitation power
circuit failure
14 A/D(S) Fault
A/D converter failure
(Signal)
15 A/D(I) Fault
A/D converter failure
(Excitation current)
16 Analog Fault
Analog circuit failure
17 Coil Open
Flowtube coil is
open-circuit
18 Coil Short
Flowtube coil is
short-circuit
19 Excite Error
Excitation circuit
failure
20 Pulse Error
Discrepancy of
pulse count
21 EEPROM
EEPROM default
Dflt
values
Note: • Alarm is output only when [F10:DO Function] is set to "Alarm Output."
• The operation when "Open (Off) Act" is set for [F11:DO Active Mode] is shown in above table.
*: The output value is performed in accordance with the setting of the burnout switch. For information about this switch, read Subsection
11.3.1.
(2) Display and output condition for process alarms
Alarm description
30 Sig Overflow
Input signal error
31 Empty Pipe
Flowtube is not filled
with fluid
32 H/L Alm
H/L Alarm
33 Adhesion Alm
Electrode adhesion
alarm
Note: • larm is output only when F10: DO Function is set to "Alarm Output."
• The operation when "Open (Off) Act" is set for F11: DO Active Mode is shown in above table.
• 4-20mA output upon the occurrence of an alarm will be fixed at the value selected with G25: 4-20mA Process Alarm.
*: Although outputs are continuous, output values are not guaranteed.
Alarm
4-20mA
Totalization
output
output
Closed
Normal
Normal
(ON)
Open
Fixed at
Indetermination
(Off)
3.2mA or less
otherwise
21.6mA or
more (*)
Open
Fixed at
Stopped
(Off)
3.2mA or less
otherwise
21.6mA or
more (*)
Selection
Alarm
4-20 mA
(parameter
output
output
number)
YES
Open
(G26)
(Off)
NO
Closed
Continuous
(G26)
(On)
YES
Open
(G27)
(Off)
NO
Closed
Continuous
(G27)
(On)
YES
Open
Normal
(G28)
(Off)
operation
NO
Closed
(G28)
(On)
YES
Open
(G29)
(Off)
NO
Closed
Continuous
(G29)
(On)
<6. PARAMETER DESCRIPTION>
Pulse
Normal
Indetermination
Stopped
Pulse
Totalization
output
Fixed
Stopped
Stopped
Continuous
Continuous
(*)
(*)
(*)
Fixed
Stopped
Stopped
Continuous
Continuous
(*)
(*)
(*)
Normal
Normal
operation
operation
Fixed
Stopped
Stopped
Continuous
Continuous
(*)
(*)
(*)
6-42
Alarm
Display unit
record
Display Mode
No
Indetermination
Indetermination
Alarm Mode
Recorded
(display of
system Alarm
message)
Alarm
Displayunit
record
Alarm Mode
Recorded
(Message)
Display
No
Mode
Alarm Mode
Recorded
(Message)
Display
No
Mode
Alarm Mode
No
(Message)
Display
Mode
Alarm Mode
Recorded
(Message)
Display
No
Mode
IM 01E30D01-01EN

Advertisement

Table of Contents
loading

Table of Contents