YOKOGAWA ADMAG AXR User Manual page 69

Two-wire magnetic flowmeter integral flowmeter
Table of Contents

Advertisement

[B30: Total Unit] Setting of units for totalization
scale
→ This setting is linked with that of parameter D10.
This parameter selects the flow rate units for use in
totalization.
Item
n Unit/P
10
 FU
-9
u Unit/P
10
 FU
-6
m Unit/P
10
 FU
-3
Unit/P
FU
k Unit/P
10
 FU
3
M Unit/P
10
 FU
6
Pulse/s
Number of pulses to be counted for one second
at 100% output.
FU: Flow rate unit selected in B21/C40: Base Flow Unit.
[B31: Total Scale] Setting of the totalization scale
→ This setting is linked with that of parameter D11.
The flow rate is totalized in individual counts in
accordance with this parameter's setting. If 0 is
selected, it indicates that the totalization function is
not to be used.
NOTE
If a totalization scale is specified upon ordering,
this parameter is set up before shipment;
however, if this is not the case, it will be
necessary for the appropriate value to be set up
by the user.
NOTE
• By setting the totalization scale, the
totalized value is displayed on the display
unit. The totalization scale is determined in
accordance with the settings of B30/D10:
Total Unit and B31/D11: Total Scale.
• The maximum value that can be displayed is
99999999, and if this is exceeded, the value
0 is counted once again. However, counting
stops at 99999999 when the totalization
switch function is used.
• If multiple ranges are being used, the flow
rate span for the smallest range becomes
the standard for the D13: Total Low Cut
setting value.
• Totalization for the reverse flow rate and for
the differential flow rate is carried out only
when "Fwd/Rev Ranges" is selected for F10:
DO Function.
Description
<6. PARAMETER DESCRIPTION>
• The totalized units are indicated on the
display unit when B31/D11 is 0.00001,
0.0001, 0.001, 0.01, 0.1, 1, 10, 100, 1000,
or 10000. In the case of other setting values,
the totalized units are not indicated.
Example 1: To count in 1 Ml (mega-liter) steps
with flow rate span = 1000 m
Since 1 Ml = 10
for B30/D10, and 1 is set for B31/
3
D11. "x10
totalized units in the Display Mode.
Example 2: T o count in 10 l (liter) steps with flow
rate span = 100 m
Since 1 l = 10
for B30/D10, and 10 is set for B31/
-2
D11. "x10
totalized units in the Display Mode.
Example 3: T o count in 5 l (liter) steps with flow
rate span = 100 m
Since 1 l = 10
for B30/D10, and 5 is set for B31/
D11. Since B31/D11 is not 0.00001,
0.0001, 0.001, 0.01, 0.1, 1, 10, 100,
1000, or 10000, there is no indication
of totalized units in the Display Mode.
• Setting of totalization scale is not possible
when specific selections have been made
for B30/D10: Total Unit, B31/D11: Total
Scale, and B23/C42: Flow Span. In such
a case, a setting alarm will be displayed,
and parameters should be changed in
accordance with the instructions given.
[B32: Pulse Unit] Setting of the pulse units
→ This setting is linked with that of parameter E10.
This parameter selects the flow rate units to be
used for pulse output.
Item
n Unit/P
10
 FU
-9
u Unit/P
10
 FU
-6
m Unit/P
10
 FU
-3
Unit/P
FU
k Unit/P
10
 FU
3
M Unit/P
10
 FU
6
Pulse/s
Number of pulses to be output for one second at
100% output.
FU: Flow rate unit selected in B21/C40: Base Flow Unit.
6-18
3
/h
3
3
x m
, k Unit/P is set
3
m
" is indicated for the
3
/h
-3
3
x m
, m Unit/P is set
3
m
" is indicated for the
3
/h
-3
3
x m
, m Unit/P is set
Description
IM 01E30D01-01EN