b. Confirm the new HART protocol revision
number
Call up the Universal rev parameter, and confirm
that the new HART revision number is displayed.
• Procedure to call up the Universal rev.
parameter.
DD
Device Setup → Detailed setup
→ Device information → Field
device information → Revision #'s
→ Universal rev →
DTM
Configuration → HART →
Universal rev. →
5
HART protocol revision: 5
7
HART protocol revision: 7
HART protocol revision can also be confirmed on
the second line and third line of the device display.
• Procedure to call up the Display Select
Second
DD
Device setup → Detailed setup →
line
Function Set → Display → Display
Select2
DTM
Configuration → Display Set →
Display Select2
Third
DD
Device setup → Detailed setup →
line
Function Set → Display → Display
Select3
DTM
Configuration → Display Set →
Display Select3
Protocol Revision
HART Protocol Revision 5
HART Protocol Revision 7
8.8.6 Other operations for the HART
configuration tool
Regarding other operations for the HART
configuration tool, read the HART configuration tool
operations manual.
<8. OPERATION VIA HART CONFIGURATION TOOL (HART 5)>
Displayed on AXR screen
HART5
HART7
8-7