8.4

Basic Setup

 Confirmation and Change of Tag and
Device Information
The tag number and device information can be
checked as follows:
• The location for the tag number and device
information
(DD)
Tag
Device Setup → Detailed Setup
→ Basic setup → Tag
Descriptor
Device Setup → Detailed Setup
→ Device information → Field device
information → Descriptor
Message
Device Setup → Detailed Setup
→ Device information → Field device
information → Message
Date
Device Setup → Detailed Setup
→ Device information → Field device
information → Date
(DTM)
Tag
Easy Setup → Tag
or Configuration → HART → Tag
Descriptor
Configuration → Device infomation 1
→ Descriptor
Message
Configuration → Device infomation 1
→ Message
Date
Configuration → Device infomation 1
→ Date
When changing the tag number or device
information, enter the information directly within the
following limitations.
Item
Number and characters
Tag
8
Descriptor
16
Message
32
Date
2/2/2 (mm/dd/yy)
• mm : month
• dd : day
• yy : year
<8. OPERATION VIA HART CONFIGURATION TOOL (HART 5)>
8.5 Parameters Configuration
The parameter structure of the HART configuration
tool is hierarchical.
Read Section 8.9 or Section 8.10, Menu Tree
Example for the corresponding parameters.
The menu tree shows a cross-reference of the
parameters for HART and BRAIN.
Read Chapter 6 for the functions of parameters.
Note that some display parameters of AXR are
different from those of HART configuration tools.
8.6

Data Renewing

There are two methods to load the AXR data
from/to HART Configuration Tool --- periodic data
renewing and discretionary data renewing. Read
Section 8.9 or Section 8.10 menu tree for each
corresponding parameter.
(1) Periodic Data Renewing
The data is updated 0.5 to 2 second cycles. The
parameter of this type is marked as "D" in "Data
Renewing" of Section 8.9 or Section 8.10 menu
tree.
(2) Discretionary Data Renewing
The data can be loaded from/to the AXR when
the data save is finished to the Configuration
Tool. The parameter of this type is marked
as "S" in "Data Renewing" of Section 8.9 or
Section 8.10 menu tree.
NOTE
The AXR is not able to set parameters via its
display unit during a communication of the HART
Configuration Tool.