Zero Adjustment Function (*2):
By using the parameter setting, zero adjustment is
carried out to ensure that the output for zero flow is
0%. Zero adjustment should be carried out only when
the flowtube is filled with measurement fluid and the
flow is completely stopped by closing the valves.
During zero adjustment (450 seconds), the current
output is 10.4 mA.
 Flowtubes
Size of AXR Flowtubes:
Lay length code 1
Process
Use
Connection
Wafer
General-purpose
Use/Explosion
Proof Type
Flange
*1: The dimensions of lay length code 1 are the same as
those of the PFA lining standard lay length (lay length
code 1) in the AXF series. For details, read "EXTERNAL
DIMENSIONS."
Lay length code 2
Process
Use
Connection
General-purpose
Use/Explosion
Wafer
Proof Type
*2: Excluding the size of 65 mm, dimensions of lay length
code 2 are the same as those of PFA lining replacement
models (lay length code 2) in AXF series. Lay lengths for
special gaskets (optional codes GA, GB, GD) are different.
For details, read "EXTERNAL DIMENSIONS."
Coating:
General-purpose Use/Explosion Proof Type:
Size 25 to 100 mm (1 to 4 in.) (Wafer type),
Size 25 to 100 mm (1 to 4 in.) (Flange type):
Housing: No coating (Stainless steel surface)
Flange (Flange type only):
No coating (Stainless steel surface)
Size 150 to 200 mm (6.0 to 8 in.) (Wafer type),
Size 150 to 200 mm (6.0 to 8 in.) (Flange type):
• Housing, Flange (Flange type only)
Corrosion-resistant coating
Coating color; Mint green (Munsell 5.6 BG
3.3/2.9 or its equivalent)
Unit: mm (in.)
Integral Flowmeter
80 (3.0), 100 (4.0),
*1
150 (6.0), 200 (8.0)
25 (1.0), 40 (1.5),
50 (2.0), 65 (2.5),
*1
80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)
Unit: mm (in.)
Integral Flowmeter
25 (1.0), 40 (1.5),
50 (2.0), 65 (2.5),
*2
80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)
<12. OUTLINE>
Flowtube Material:
Size 25 to 100 mm (1 to 4 in.)
Part Name
Housing
Flange
Size 25 mm
(1.0 in.)
Mini-
Wafer
Flange
type
Size 40 to 100 mm
(1.5 to 4.0 in.)
Size 25 mm
(1.0 in.)
Wafer
type
Size 40 to 100 mm
(1.5 to 4.0 in.)
Pipe
Size 25 mm
(1.0 in.)
Flange
type
Size 40 to 100 mm
(1.5 to 4.0 in.)
Size 150 mm (6.0 in.) to 200 mm (8.0 in.)
Part Name
Housing
Process Connection code: B**
Flange
Process Connection code: C**
Mini-
Wafer Type
Flange
Pipe
Flange Type/Wafer Type
Wetted Part Material:
Lining;
Fluorocarbon PFA
lining
*1
*1: PFA is FDA (U.S. Food and Drug Administration)
approval material.
The inner surface of the PFA lining is mirror-finished to
Ra of 0.05 to 0.15 μm. The value of Ra is the average
of measurements at several points. Mirror finished
PFA lining is standard for size 25 to 100 mm (1 to 4
in.) and optional for size 150 to 200 mm (6 to 8 in.)
specified by optional code PM.
Electrode;
Stainless steel-JIS SUS316L (AISI 316L SS/EN
1.4404 equivalent), HASTELLOY C-276
lent, Tantalum, Platinum-Iridium
12-4
Material
Stainless steel-JIS
SUS304
(AISI 304 SS/EN 1.4301
equivalent)
Stainless steel-JIS
SUS304 or SUSF304
(AISI 304 SS/EN 1.4301
equivalent)
Stainless steel-SCS13
Stainless steel-JIS
SUS430
ASTM 4300/DIN
X6Cr17/ EN 1.4016
equivalent
Stainless steel-SCS13
Stainless steel-JIS
SUS304
(AISI 304 SS/EN 1.4301
equivalent)
Stainless steel-SCS13
Stainless steel-JIS
SUS304
(AISI 304 SS/
EN 1.4301 equivalent)
Material
Carbon steel-JIS SPCC
equivalent
Stainless steel-JIS
SUS304 or SUSF304
(AISI 304 SS/EN 1.4301
equivalent)
Carbon steel-JIS SS400
or SFVC 2A
Carbon steel-JIS SS400
or SFVC 2A
Stainless steel-JIS SUS
304 (AISI 304 SS/EN
1.4301 equivalent)
equiva-
*1
IM 01E30D01-01EN