(6) Item F (Menu F): Status Functions Setting items
Menu F contains items relevant to multiplex range output and other status Output.
Name
Item
R/W
Display unit
(BRAIN)
F00 Status Function
(STATUS FUNC)
F10 DO Function
(DO FUNCTION)
F11 DO Active Mode
(DO ACT MODE)
F20 Forward Span2
(FWD SPAN2)
F21 Reverse Span
(REV SPAN)
F30 Auto Range Hys
(AUTO RNG HYS)
F31 Bi Direction Hys
(BI DIREC HYS)
F60 —
(SELF CHECK)
Data range
Units
Display unit
/BRAIN
W
No Function
Pulse Output
Alarm Output
Warning Output
Total Switch
H/L Alarm
Fwd/Rev Rngs
Auto 2 Rngs
W
Closed(On) Act
Open(Off) Act
W
0.00001 to 32000
C40
/C41
W
0.00001 to 32000
C40
/C41
W
0 to 15
W
0 to 8
R
Good
Error
<6. PARAMETER DESCRIPTION>
Position
Default value
of decimal
(*): Indicated item
point
Pulse Output
Closed(On) Act
0 to 4
1 m/s
0 to 4
1 m/s
%
0
10 %
%
0
2 %
6-8
Description
Selects function for the DO
terminal
Selects whether DO terminal
will be set to "On Active" or "Off
Active".
Sets flow rate span for forward
No. 2 range
Sets flow rate span for reverse
range
Sets hysteresis width for
automatic range switching
Sets hysteresis width for
forward/reverse switching
Read Section 6.5 "Alarm
Functions".