(6) Name Plate
MODEL: Specified model code
SUFFIX: Suffix codes of the model code
STYLE: Specified style code
SIZE: Nominal size of apparatus
METER FACTOR: Sensor constant number of apparatus
SUPPLY: Supply voltage of apparatus
OUTPUT: Output signal of apparatus
FLUID PRESS.: Fluid pressure of apparatus
FLUID TEMP.: Fluid temperature of apparatus
AMB. TEMP., Tamb: Ambient temperature
POWER SUPPLY/CURRENT OUTPUT:
Power supply with output signal of apparatus
DIGITAL OUTPUT: Output signal of apparatus
NO.: Manufacturing serial number
No.: IECEx DEK 11.0053
IECEx Type Examination certificate number
Ex db e ia IIC T6...T4 Gb
Protection type and temp. class for gas
Ex tb IIIC T90°C, T110°C, T130°C Db
Protection type and maximum surface temp. for dust
ENCLOSURE: Enclosure protection code
ELECTRODE CIRCUIT Um: Voltage of electrode circuit
WARNING: Warning to apparatus
Name of manufacturer.
*1: The product-producing country
<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14.5 TIIS

The model AXRC magnetic flowmeter
with optional code JF3, which has obtained
certification according to technical criteria
for explosion proof construction of electric
machinery and equipment (Standards
Notification No. 556 from the Japanese
Ministry of Labor) conforming to IEC standards,
is designed for hazardous areas where
inflammable gases or vapors may be present.
(This allows installation in Zone 1 and 2 areas)
To preserve the safety of flameproof equipment
requires great care during mounting, wiring,
and piping. Safety requirements also place
restrictions on maintenance and repair activities.
Users absolutely must read "INSTALLATION
AND OPERATING PRECAUTIONS FOR TIIS
FLAMEPROOF EQUIPMENT" at the end of this
manual.
(1) Technical Data
Certificate:
Size: mm(inch)
25 (1.0)
40 (1.5)
50 (2.0)
65 (2.5)
80 (3.0)
100 (4.0)
150 (6.0)
200 (8.0)
Construction: Ex d e [ia] IIC T4
Gas Group And Temperature Class: IIC T4
 Non-intrinsically safety circuit
• Supply Voltage: 14.7 to 42 V dc
• Output Signal: 4 to 20 mA dc
• Digital Output: ON; 2 V dc, 120 mA
• Allowable Voltage (Um): 250 V ac 50/60 Hz,
• Excitation Circuit: 29 V
CAUTION
Wafer Type -A**
TC19746
TC19747
TC19748
TC19749
TC19750
TC19751
TC19753
TC19756
Converter: Flameproof enclosure
and intrinsically safety (ia)
Flowtube: Increased safety and
intrinsically safety (ia)
Electrode: Intrinsically safety (ia)
OFF; 30 V dc, max., 4 mA
250 V dc
14-8
Flange Type -B**
TC19746
TC19747
TC19748
TC19749
TC19750
TC19751
TC19754
TC19757
IM 01E30D01-01EN