Model And Suffix Code - YOKOGAWA ADMAG AXR User Manual

Two-wire magnetic flowmeter integral flowmeter
Table of Contents

Advertisement

12.5 MODEL AND SUFFIX CODE

● Wafer Type
Model
Suffix Code
AXR025
----------------------------------------
AXR040
----------------------------------------
AXR050
----------------------------------------
AXR065
----------------------------------------
AXR080
----------------------------------------
AXR100
----------------------------------------
AXR150
----------------------------------------
AXR200
----------------------------------------
Use
G
----------------------------------------
C
----------------------------------------
Output Signal
-D -----------------------------------
and
Communication
-E -----------------------------------
-J -----------------------------------
Power Supply
1 ---------------------------------
Lining (*2)
A ------------------------------
Electrode Material (*2)
L ---------------------------
P ---------------------------
H ---------------------------
T ---------------------------
Electrode Structure
1 ------------------------
Grounding Ring and
N --------------------
Grounding Electrode
S --------------------
Material (*2)
L --------------------
P --------------------
H --------------------
T --------------------
Process Connection
(*4) (*5)
Lay Length
Electrical Connection (*9)
Indicator (*10)(*11)
Calibration
Options
Note: An exclusive User's Manual might be attached for products whose suffix code or optional codes contain code "Z".
Please read it along with their standard manual.
*1: For explosion proof types, specify types of explosion proof certification using the optional codes.
For the TIIS flameproof type, select optional code G11. Available only for JIS G1/2 female electrical connections.
Available only for wiring of using a flameproof packing adapter approved by Yokogawa.
The flameproof metal conduit wiring for TIIS flameproof type is not permitted.
*2:
U sers must consider the characteristics of selected wetted parts material and influence of process fluids.
The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the instrument itself can be damaged and that fragments from the instrument can contami-
nate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*3: Available only for metal piping.
*4: Mating dimensions are based on standards as follow:
ANSI: ASME B 16.5, DIN: DIN 2501, JIS: JIS B 2220 and JIS G 3443-2
Size 25 mm (1 in.)
Size 40 mm (1.5 in.)
Size 50 mm (2 in.)
Size 65 mm (2.5 in.)
Size 80 mm (3 in.)
Size 100 mm (4 in.)
Size 150 mm (6 in.)
Size 200 mm (8 in.)
General-Purpose Use
Explosion proof Type (*1)
Integral Flowmeter with 4 to 20 mA DC Output and digital
communication (BRAIN protocol)
Integral Flowmeter with 4 to 20 mA DC Output and digital
communication (HART protocol) (*12)
Integral Flowmeter with 4 to 20 mA DC Output with digital
communication (HART5/HART7 protocol) (*13)
Integral Flowmeter Operating voltage range 14.7 to 42 V DC
Two-wire system
Fluorocarbon PFA
JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)
Platinum-iridium
HASTELLOY C-276 Equivalent
Tantalum
Non-replaceable
None (*3)
JIS SUS316 (AISI 316 SS/EN 1.4401 Equivalent)
JIS SUS316L or ASTM 316L (AISI 316L SS/EN 1.4404 Equivalent)
Platinum-iridium
HASTELLOY C-276 Equivalent
Tantalum
-AA1 -------------
ANSI Class 150
-AA2 -------------
ANSI Class 300
-AD1 -------------
DIN PN 10
-AD2 -------------
DIN PN 16
-AD4 -------------
DIN PN 40
-AJ1 -------------
JIS 10K
-AJ2 -------------
JIS 20K
-AG1 -------------
JIS F12 (JIS75M)
1 ---------------
Lay length code 1 (*7)
2 ---------------
Lay length code 2 (*8)
-0 -----------
JIS G1/2 female
-2 -----------
ANSI 1/2 NPT female
-4 -----------
ISO M20 × 1.5 female
1 ---------
Integral Flowmeter with indicator (Horizontal)
2 ---------
Integral Flowmeter with indicator (Vertical)
N --------
Integral Flowmeter without indicator
B ----- Always B
/
Optional code (Read the Table of Optional Specifications)
<12. OUTLINE>
Description
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Two-wire Magnetic Flowmeter Integral Flowmeter
Wafer
Wafer
Wafer (*6)
Wafer (*6)
Wafer (*6)
Wafer
Wafer
Wafer
12-9
Applicable Model
Size 200 mm (8.0 in)
Size 65 mm (2.5 in.) to
200 mm (8.0 in.)
Size 25 mm (1.0 in.) to
50 mm (2.0 in.)
Size 80 mm (3.0 in.) to
200 mm (8.0 in.)
Size 80 mm (3.0 in.) to
200 mm (8.0 in.)
IM 01E30D01-01EN

Advertisement

Table of Contents
loading