3-6-4 Expiry date/time settings: LMT

Configures the "expiry" function used to mark the date with a specified period added or subtracted to/from the current date.
⿎ Setting request data / response data for readout
Start
LMT
code
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request
Start
LMT
code
⿎ Data description
Name
Omit
Expiry time No.
Periods
Y
Expiry time unit
Y
Today included
Y
Total data length
* Setting request data are variable length.
⿎ Example of command settings
Condition:
Expiry time No. = 1, Periods = 6, Expiry time unit = 2, Today included = 0
• Setting
Transmission data
• Readout
Transmission data
Response data
88
[Expiry time No.], [Periods],
Sub
[Expiry time unit], [Today included]
command
[Expiry time No.]
R
Max. 2-byte
Data length
Data contents
[byte]
Max. 2*
"01"–"32"
Max. 4*
"-999"–"+999"
"0": Year
"1": Month
"2": Date
1
"3": Hour
"4": Minute
"0": Today not included
1
"1": Today included
Max. 11
It is the length including the separator ",".
[STX]
LMT
[STX]
LMT
[STX]
LMT
Max. 11-byte
(Check sum)
"17" to "32" are the global expiry date/time.
It is the period added or subtracted to/from the
current date and time.
It is the unit of the period added or subtracted to/
from the current date and time.
Specifies whether or not to include today in the base
date for addition or subtraction.
It is valid when the expiry time unit is year or month.
S
1,6,2,0
[CR]
R
1
[CR]
A
01,+006,2,0
[CR]
ME-LPGS-SR-5
(Check sum)
End code
End code
Remarks