Name
Omit
Count individually
Y
Count direction
Y
Count "Mark OFF"
Y
Counter starting
Y
position
Total data length
* Setting request data are variable length.
Reference
• When Step & repeat ON/OFF is set to "OFF", the subsequent data after "base position" do not exist in the response data
for readout.
⿎ Example of command settings
Condition:
Object group No. = 1, Step & repeat ON/OFF = 1, Base position = 0,
Number of rows = 12, Number of columns = 4, Row step = 4, Column step = 8.5,
Count individually = 1, Count direction = 1, Count "Mark OFF" = 0, Counter starting position = 0
• Setting
Transmission data
• Readout
Transmission data
Response data
Data
length
Data contents
[byte]
"0": OFF (same count value)
1
"1": ON (count individually)
"0": Horizontal
1
"1": Vertical
"0": No
1
"1": Yes
"0": Top left
"1": Top right
1
"2": Bottom left
"3": Bottom right
"A": Base position
Max. 42
It is the length including the separator ",".
[STX]
SRC
S
[STX]
SRC
R
[STX]
SRC
A
ME-LPGS-SR-5
If the product counts individually,
the counter value will be
updated for each marking data
of Step & repeat.
If the product does not count
individually, the counter value of
Step & repeat will be the same
value for all data in a single
marking operation.
Specifies the count direction
within the marking data when
the product counts individually.
Specifies if the product will or
will not count the counter value
of the marking data with Mark
OFF specified by Step & repeat
fine-adjustment when the
product counts individually.
When "Count individually"
is enabled, specify the start
position of the counting.
1,1,0,12,4,4,8.5,1,1,0,0
1
[CR]
0001,1,0,0012,0004,004.000,008.500,1,1,0,0
Remarks
[CR]
[CR]
135