3-5-4 Reference character: SST

Sets the characters strings as the "reference character" which can be used in several character objects commonly.
⿎ Setting request data
Start
SST
code
⿎ Readout request data
Start
SST
code
⿎ Response data for readout
Start
SST
code
⿎ Data description
Data length
Name
[byte]
String No.
Max. 3*
Reference
Max. 198
character
Total data length
Max. 202
* Setting request data are variable length.
Reference
• Refer to "2-3-6 Character data input method" (P.38) for details on the character input method and character types with
input restrictions.
• For response data for readout, the characters input with the one-byte characters are read out in ASCII code. The
characters input with the two-byte characters are read out in the character code, Shift JIS code or GB 2312 code,
selected in the system settings. If any characters which belong to the non-supported character code are in the data, the
readout request cannot be accepted.
• To set the reference character in the character object, use LNO command (Applying reference character).
⿎ Example of command settings
Condition:
String No. = 1, Reference character = abcd, String No. = 101,
Reference character = %06:CG (counter function)
• Setting
Transmission data
Condition:
String No. = 1, Reference character = abcd
• Readout
Transmission data
Response data
[String No.], [Reference character]
S
(, [String No.], [Reference character]...)
[String No.]
R
Max. 3-byte
[String No.], [Reference character]
A
Max. 202-byte
Data contents
"001"–"200"
The number of input characters
allowed is max. 99 characters.
It is the length including the separator ",".
The maximum value that can be set to one string number.
Max. 32 strings can be set at once. Note that the total data length of one request data
should be less than 4096-byte.
[STX]
SST
[STX]
SST
[STX]
SST
(Check
End code
sum)
(Check
sum)
• Specifies the row number in the reference
list to input character strings.
• "101" to "200" are the global character
strings that can be used in another files
commonly.
Specify 0-byte for data length to delete
characters.
S
1,abcd,101,%06:CG
R
1
[CR]
A
001,abcd
[CR]
ME-LPGS-SR-5
(Check
End code
sum)
End code
Remarks
[CR]