Communication Settings - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

1-4-2 Communication settings

Item
Communication protocol
Standards
Applicable cable
Applicable HUB (or rooter)
IP address
Subnet mask
Default gateway
PC configuration software port
Command communication port
* Do not use "127" in the first octet.
Reference
• The communication control of the laser marker through the Ethernet should be performed in a secure network settings.
• Even the IP Address and Subnet Mask values are within the configurable range, they may not be available depending
on the combination.
• For the details of the communication settings, refer to "1-1-3 Settings before external control" (P.15).
⿎ Ethernet communication settings for communication command control
Item
Start code *
Response data command *
Response data sub
command *
Character code
Encoding for 2-byte
characters *
Check sum
End code
Reception timer
* If you set "LP-400/V compatibility" in the system settings of Laser Marker NAVI smart, the same command format with
the previous models of LP-400/LP-V series is applied regardless these settings. For the details, refer to the "Serial
Communication Command Guide: LP-400/V compatible mode".
24
Ethernet communication settings
TCP/IP
IEEE802.3 (10BASE-T) / IEEE802.3u (100BASE-TX)
Category 5 or higher
10BASE-T / 100BASE-TX compatible
1.0.0.0 to 223.255.255.255 * (Initial value: 192.168.1.5)
128.0.0.0 to 255.255.255.254 (Initial value: 255.255.255.0)
1.0.0.0 to 223.255.255.255 * (Initial value: 0.0.0.0 (Unspecified))
1025 to 65534, except 9090 (Initial value: 9093)
1025 to 65534, except 9090 (Initial value: 9094)
Ethernet communication settings
ON (STX) / OFF (initial setting: STX)
ON / OFF (initial setting: ON)
Any single byte character of ASCII code from 01(HEX) to 7F(HEX) can be specified.
• Initial setting of positive response code: A
• Initial setting of negative response code: E
• Initial setting of read request response code: A
ASCII code
Shift-JIS / GB 2312 (initial setting: Shift-JIS)
OFF
CR
Timeout monitoring ON (10 sec.)
ME-LPGS-SR-5

Hide quick links:

Advertisement

Table of Contents

Troubleshooting