File Name: Fnm - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-4-5 File name: FNM

Sets the file name of the file number selected.
⿎ Setting request data / response data for readout
Start
FNM
code
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
FNM
code
⿎ Data description
Data length
Name
[byte]
File name
Max. 254
Total data
Max. 254
length
Reference
• Refer to "2-3-6 Character data input method" (P.38) for details on the character input method and character types with
input restrictions.
• If the file name contains any characters which belong to the non-supported character code, the file name cannot be
readout.
• Set one or more characters for this command. You cannot delete file names.
⿎ Example of command settings
Condition:
File name = abcd
• Setting
Transmission data
• Readout
Transmission data
Response data
74
Sub
[File name]
command
Max. 254-byte
R
(Check sum)
Data contents
The number of input characters
allowed is 1 to 127 characters.
[STX]
[STX]
[STX]
(Check sum)
End code
FNM
S
abcd
[CR]
FNM
R
[CR]
FNM
A
abcd
[CR]
ME-LPGS-SR-5
End code
Remarks