• Trigger mode setting is applied to only the selected file. When using several files, set the trigger mode for each file.
• The default setting of the trigger mode is "single trigger".
• These settings are not applied to on-the-fly marking. Set the trigger mode of on-the-fly marking with FLY command (motion
settings for all files).
• MRK command can be used when the trigger mode is set to "single trigger". When the trigger mode is set to "continuous
trigger", input the marking trigger by using TRIGGER IN signal in I/O terminal.
⿎ Data example
Condition:
Trigger mode = 1, Allow to stop halfway = 0, Minimum number of scans = 8,
Maximum number of scans = 10, Scan interval = 0.1
• Setting
Transmission data
• Readout
Transmission data
Response data
Condition:
Trigger mode = 0
• Setting
Transmission data
• Readout
Transmission data
Response data
64
[STX]
TMS
S
1,0,8,10,0.1
[STX]
TMS
R
[CR]
[STX]
TMS
A
1,0,0008,0010,00.1
[STX]
TMS
S
0
[STX]
TMS
R
[CR]
[STX]
TMS
A
0