3-14-2 Error code: ENO
Reads out the error code of alarm or warning when an error has occurred.
⿎ Readout request data
Start
ENO
code
⿎ Response data for readout
Start
ENO
code
⿎ Data description
Data length
Name
Error code
Total data length
⿎ Example of command settings
Condition:
When error E600 occurs
• Readout
Transmission data
Response data
Reference
• Refer to "Error Indication" (P.169) for details on error codes.
3-14-3 Alarm reset: ARS
The reset input for restoring the system from the alarm status. Make sure to verify the safety by eliminating the alarm
causes before transmitting this command.
⿎ Setting request data
Start
ARS
code
⿎ Example of command settings
• Setting
Transmission data
Reference
• The alarms you can clear by the alarm reset are as follows:
• E400 to E499
• E500 to E599
• This command can also be used for resetting the states of warnings (E601 to E799).
• For the alarms you are unable to reset such as the ones caused by hardware or system error, restart the laser marker.
R
(Check sum)
[Error code]
A
3-byte
Data contents
[byte]
"000": No error
3
"001"–"999": Error codes
3
The data length is fixed.
[STX]
ENO
[STX]
ENO
S
(Check sum)
[STX]
ARS
End code
(Check sum)
R
[CR]
A
600
[CR]
End code
S
[CR]
ME-LPGS-SR-5
End code
Remarks
153