3-13 Laser Setting Commands

3-13-1 Laser settings: LSC

Sets the laser settings for the entire file such as laser power and scan speed.
Reference
• The settings by this command are applied to all objects in the file. If you want to change the laser power/scan speed
correction value of the specified object only, use the laser correction by object (MOD) command.
⿎ Setting request data / response data for readout
Start
LSC
code
command
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
LSC
code
⿎ Data description
Name
Laser power
Scan speed
Laser frequency
or
Laser pulse cycle
Total data length
* Setting request data are variable length.
[Laser power], [Scan speed],
Sub
[Laser frequency/Laser pulse cycle]
LP-GS/LP-RC: Max. 14-byte
R
(Check sum)
Data
Omit
length
[byte]
LP-GS051(-L)
Y
Max. 5*
LP-GS052
LP-RC350S
LP-RF200P
Model
LP-GS051
LP-GS052
Y
Max. 5*
LP-GS051-L
LP-RC350S
LP-RF200P
Model
LP-GS051(-L)
Max. 2*
LP-GS052
Y
or
Max. 5*
LP-RC350S
LP-RF200P
Max. 14
It is the length including the separator ",".
or
• LP-GS/LP-RC series: Max. 14-byte
Max. 17
• LP-RF series: Max. 17-byte
LP-RF: Max. 17-byte
End code
Data contents
Model
Setting range
"000.1"–"100.0"
"012.0"–"100.0"
Setting range [mm/s]
"00001"–"03000"
"00001"–"02000"
"00001"–"12000"
Setting range
"05", "10", "20" [kHz]
"40" [kHz]
"005.0"–"050.0" [μs]
ME-LPGS-SR-5
(Check sum)
End code
Remarks
• For LP-GS/LP-RC series,
set the laser frequency (Max.
2-byte).
• For LP-RF series, set the
laser pulse cycle (Max.
5-byte).