3-14 Maintenance Commands

3-14-1 Laser radiation for measurement: SPT

Controls "laser radiation for measurement" used to measure laser output by a commercially available power meter.
⿎ Setting request data / response data for readout
Start
SPT
code
command
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
SPT
code
⿎ Data description
Name
Omit
Radiation
on/off
Laser power
Y
Laser
frequency
or
Y
Laser pulse
cycle
Apply system
offset to laser
Y
power
Total data length
* Setting request data are variable length.
[Radiation on/off], [Laser power],
[Laser frequency/Laser pulse cycle],
Sub
[Apply system offset to laser power]
LP-GS/LP-RC: Max. 12-byte
LP-RF: Max. 15-byte
R
(Check sum)
Data
length
Data contents
[byte]
"0": Stop radiation (Radiation OFF)
1
"1": Start radiation (Radiation ON)
Model
LP-GS051(-L)
Max. 5*
LP-GS052
LP-RC350S
LP-RF200P
Model
LP-GS051(-L)
Max. 2 *
LP-GS052
or
Max. 5 *
LP-RC350S
LP-RF200P
"0": Do not apply
1
"1": Apply
Max. 12
It is the length including the separator ",".
or
• LP-GS/LP-RC series: Max. 12-byte
Max. 15
• LP-RF series: Max. 15-byte
End code
Setting range
"000.1"–"100.0"
"012.0"–"100.0"
Setting range
"05", "10", "20" [kHz]
"40" [kHz]
"005.0"–"050.0" [μs]
ME-LPGS-SR-5
(Check sum)
End code
Remarks
• The internal shutter is automatically
opened and closed at the time of
start and stop of radiation.
• In the readout data this field
indicates the emission on/off of the
laser radiation for measurement.
• To set the subsequent settings
without laser radiation, set the
radiation on/off to "0".
When this data is omitted, laser is
radiated with the power used in the last
settings (or the initial value 20 if the
power has not been specified).
• For LP-GS/LP-RC series, set the
laser frequency (Max. 2-byte).
• For LP-RF series, set the laser
pulse cycle (Max. 5-byte).
Specifies whether the system offset
value of laser power applies to the
power settings of this function or not.