Counter Reset Timing: Crc - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-6-3 Counter reset timing: CRC

Sets the timing to reset the counter automatically.
⿎ Setting request data / response data for readout
Start
CRC
Sub command
code
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
CRC
code
⿎ Data description
Name
Data length [byte]
Counter No.
System reserved value
Reset at date change
Total data length
* Setting request data are variable length.
Reference
• If the counter is reset at date change during on-the-fly marking operation (single trigger mode), the marking trigger ready
status turns off momentary and there is a case that the next marking could not be executed due to Warning E751.
⿎ Example of command settings
Condition:
Counter No. = 10, System reserved value = 0, Reset at date change = 1
• Setting
Transmission data
• Readout
Transmission data
Response data
[Counter No.], [System reserved value],
[Reset at date change]
[Counter No.], [System reserved value]
R
Max. 4-byte
Max. 2*
"00"–"31"
1
"0": Fixed
"0": No auto reset setting
1
"1": Resets when the date is
updated
Max. 6
It is the length including the separator ",".
[STX]
CRC
[STX]
CRC
[STX]
CRC
Max. 6-byte
Data contents
S
10,0,1
[CR]
R
10,0
[CR]
A
10,0,1
[CR]
ME-LPGS-SR-5
(Check sum)
(Check sum)
End code
Remarks
"16" to "31" are the global counters.
• It is the setting to reset the counter
when the system clock date of the
laser marker is updated.
• The counter reset at date change
cannot be used with on-the-fly
marking at regular intervals or
on-the-fly marking with multiple
triggers.
End code
87

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents