Error Indication; Alarm: E001 - E599 - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

Error Indication

When an error occurs, an error code appears on the display panel of the laser marker.
Errors are categorized into alarm and warning depending on their details.
This chapter describes the details and measures of errors.

Alarm: E001 - E599

Errors that occur when highly emergent safety function is activated or there is any abnormality in laser marker are output as
alarm.
When an alarm occurs, the laser supply (laser pumping) is turned OFF, and the laser radiation is stopped if during the
lasing process.
⿎ Release method of alarm
1. Remove a cause of alarm and confirm the safety. (Any alarms due to hardware's problem cannot be released.)
2. For error codes E400 to E599, use any of the following means to input the alarm reset.
• Click the confirmation button in the error dialog on the configuration software Laser Marker NAVI smart screen.
• Turn ON ALARM RESET IN (X15) on the I/O terminal block.
• Use the serial communication (RS-232C or Ethernet) to transmit an alarm reset command (ARS).
For the alarms you are unable to reset such as the ones caused by hardware or system error, restart the laser marker.
3. If any alarm occurs during marking of files that use the counter, check the counter value before resuming marking.
ERROR
CODE
E001 - E038
E045 - E094
E101 - E138
E145 - E194
E202
An error has occurred to the internal system of
E208 - E214
the laser marker.
E223 - E224
E230
E245 - E248
E300 - E380
E039
• Incorrect combination of the head and
E044
controller connected.
E139
• The cable between the head and controller is
E144
not connected correctly.
• Communication between the head and
E040 - E043
controller cannot be performed due to an error
E140 - E143
with the internal system.
E221 - E222
• The cable between the head and controller is
E240 - E243
not connected correctly.
E200 - E201
INTERLOCK safety relay is out of order.
*2
• Abnormality occurs on the internal shutter.
E205 - E207
• Head control cable is not connected properly.
E220
Laser head housing is open.
Description
ME-LPGS-SR-5
Measures *1
Check the connection of the cable and various
signal lines, and then restart the laser marker.
• Check the model name and the serial number
of head and controller. Connect models in the
correct combination.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
• Replace the cable.
Contact our sales office or representatives.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
Contact our sales office or representatives.