3-3-8 Guide laser: GID

Supported model: LP-GS051(-L) type / LP-RC350S / LP-RF series
Controls radiation of red guide laser for marking position confirmation.
⿎ Setting request data / response data for readout
Start
GID
code
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
GID
code
⿎ Data description
Name
Omit
Guide laser
display
Guide laser
Y
scan speed
Guide laser
Y
Z-movement
Total data length
* Setting request data are variable length.
Reference
• To radiate the guide laser with this command, set the guide laser display control method to "communication commands"
by Laser Marker NAVI smart.
• You can start the guide laser radiation only with the internal shutter closed.
• The guide laser stops automatically after about one minute has passed from the startup.
• When on-the-fly marking is set for LP-RC/LP-RF series, the guide laser of the marking image and the masked objects
operates with the on-the-fly behavior.
• For LP-GS052 type, guide laser command (GID) cannot be used.
• Do not execute any other operation including the shutter opening/closing and sending MKM command while the guide
laser is emitted.
• The settings of guide laser scan speed and guide laser Z-movement are common in all files.
• The settings of guide laser scan speed and guide laser Z-movement are saved in the laser marker without overwriting
operation.
66
[Guide laser display], [Guide laser scan speed],
Sub
command
R
(Check sum)
Data length
[byte]
"0": Stop display
"1": Marking field
1
"2": Marking image
"3": Masked objects
"4": Work distance
Model
LP-GS051
Max. 5*
LP-GS051-L
LP-RC350S
LP-RF200P
Model
LP-GS051
Max. 8*
LP-GS051-L
LP-RC350S
LP-RF200P
Max. 16
It is the length including the separator ",".
[Guide laser Z-movement]
Max. 16-byte
End code
Data contents
Setting range [mm/s]
"00001"–"03000"
"00001"–"02000"
"00001"–"06000"
Setting range [mm]
"-003.000"–"+003.000"
"+000.000" or omit
ME-LPGS-SR-5
(Check
End code
sum)
Remarks
• "1" to "4" can be used only when
the shutter is closed.
• To set guide laser scan speed or
Z-movement without guide laser
radiation, set the guide laser
display to "0".
When on-the-fly marking is set for
LP-RC/LP-RF series, this setting
is not applied to the guide laser of
the marking image and the masked
objects. To them the on-the-fly
speed is applied.
• Enabled only when the guide
laser display is set to marking
field or work distance.
• Z-movement cannot be specified
with LP-GS051-L, LP-RC and
LP-RF series.