3-6-2 Counter reset: CTR

Resets the current value to the starting value.
⿎ Setting request data
Start
CTR
code
⿎ Data description
Data length
Name
[byte]
Counter No.*
Max. 2*
Total data
Max. 2
length
* Setting request data are variable length.
Reference
• The setting changed by this command is saved in the laser marker without overwriting to the file.
• If the counter is reset during on-the-fly marking operation, the marking trigger ready status turns off momentary and
there is a case that the next marking could not be executed due to Warning E751.
⿎ Example of command settings
Condition:
To reset counter 0, 1, 2, 3
• Setting
Transmission data
86
S
[Counter No.] (,[Counter No], ...)
Data contents
"00"–"31"
The maximum value to reset one counter number.
Max. 32 counters can be reset at once.
[STX]
CTR
• "16" to "31" are the global counters.
• Two or more counter numbers can be specified using a
separator ",".
S
0,1,2,3
[CR]
ME-LPGS-SR-5