Panasonic LP-GS Series Serial Communication Command Manual page 140

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

⿎ Example of command settings
Condition:
Adjustment No. = 0, Adjustment object = 4, Object group No. = 0, Start row = 4,
Start column = 4, Last row = 8, Last column = 8, Adjustment item = 0, X-movement = 0.1,
Y-movement = -0.2, Z-movement = 0.3, Rotation movement = 2.1,
Laser power correction = -20
• Setting
Transmission data
• Readout
Transmission data
Response data
Condition:
Adjustment No. = 0, Adjustment object = 4, Object group No. = 0, Start row = 4,
Start column = 4, Last row = 8, Last column = 8, Adjustment item = 1
• Setting
Transmission data
• Readout
Transmission data
Response data
Reference
• When the adjustment item is set to Mark OFF, the subsequent data after X-movement do not exist in the response data
for readout.
140
[STX]
SRA
S
0,4,0,4,4,8,8,0,0.1,-0.2,0.3,2.1,-20
[STX]
SRA
R
0
000,4,0000,004,004,008,008,0,+000.100,
[STX]
SRA
A
-000.200,+000.300,+002.100,-20
[STX]
SRA
S
0,4,0,4,4,8,8,1
[STX]
SRA
R
0
[STX]
SRA
A
000,4,0000,004,004,008,008,1
ME-LPGS-SR-5
[CR]
[CR]
[CR]
[CR]
[CR]
[CR]

Hide quick links: